BAC S15E 1018-10 LE offener KühlturmBAC
S1500E
BAC S15E 1018-10 LE offener Kühlturm
BAC
S1500E
VB ditambah PPN
€26.800
Kondisi
Bekas
Lokasi
Borken 

Data mesin
Harga & Lokasi
VB ditambah PPN
€26.800
- Lokasi:
- 46325 Borken, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A21340202
- Nomor referensi:
- 60821
- Pembaruan:
- terakhir pada 02.06.2026
Deskripsi
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance open cooling tower from Baltimore Aircoil Company's (BAC) S1500E series.
This specific model is designed for industrial cooling applications and large-scale HVAC systems where high efficiency and ease of maintenance are priorities.
Technology
Patented BACross III fill system enables easy inspection of the fill, preventing biological growth (e.g., Legionella).
Key Features of the S1500E Series
- Maintenance Access: A large, inward-swinging access door and internal maintenance platforms allow technicians to carry out inspections conveniently while standing inside the unit.
- Hygiene Control: The design minimizes standing water and protects from sunlight through dedicated air inlet elements, reducing algae growth.
Dkodoynkbmopfx Akten
- Flexibility: The single-side air intake allows the cooling tower to be installed in confined spaces or directly against walls.
- Materials: Galvanised steel with Baltibond hybrid coating.
Typical Applications
- Industrial Cooling: Used in factories for process cooling.
- HVAC: Deployed in large building complexes as part of central cooling systems.
- Refrigeration: Serves as a condenser in commercial refrigeration circuits.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW rating, as the actual performance depends entirely on thermodynamic ambient conditions and system temperatures.
This model is rated for maximum flow rates of up to 198 litres per second.
Under typical industrial and HVAC standard conditions, the nominal cooling capacity of this model ranges approximately from 1,200 kW to 2,100 kW.
Why Does Cooling Capacity Vary?
- Wet Bulb Temperature (Ambient Air): The cooler and drier the surrounding air, the more water can evaporate, thus increasing cooling capacity.
- Water Temperatures: Performance changes significantly depending on the hot water inlet temperature (e.g., 35°C) and the cold water outlet temperature (e.g., 29°C).
- Air Volume Flow: According to BAC technical data, the S15E 1018-10 LE actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
- If the airflow is reduced by a frequency converter (e.g., during night mode or in winter), the cooling capacity decreases in a controlled manner.
- Approach: This is the most important thermodynamic factor – the difference between the desired cold water temperature and the wet bulb temperature set by physics. The closer the cold water approaches the wet bulb, the less kW the tower can achieve.
Technical Data:
Fan & Air Data
- Air volume flow: 60.0 m³/s (induced draft)
- Fan motors: 3 x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
- Water Inlet (Fluid Inlet): 1 x DN 250 (nominal diameter ND 250 mm)
- Water Outlet (Fluid Outlet): 1 x DN 300 (ND 300 mm)
- Make-up Water Connection: 1 x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
The BAC S15E 1018-10-LE is a high-performance open cooling tower from Baltimore Aircoil Company's (BAC) S1500E series.
This specific model is designed for industrial cooling applications and large-scale HVAC systems where high efficiency and ease of maintenance are priorities.
Technology
Patented BACross III fill system enables easy inspection of the fill, preventing biological growth (e.g., Legionella).
Key Features of the S1500E Series
- Maintenance Access: A large, inward-swinging access door and internal maintenance platforms allow technicians to carry out inspections conveniently while standing inside the unit.
- Hygiene Control: The design minimizes standing water and protects from sunlight through dedicated air inlet elements, reducing algae growth.
Dkodoynkbmopfx Akten
- Flexibility: The single-side air intake allows the cooling tower to be installed in confined spaces or directly against walls.
- Materials: Galvanised steel with Baltibond hybrid coating.
Typical Applications
- Industrial Cooling: Used in factories for process cooling.
- HVAC: Deployed in large building complexes as part of central cooling systems.
- Refrigeration: Serves as a condenser in commercial refrigeration circuits.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW rating, as the actual performance depends entirely on thermodynamic ambient conditions and system temperatures.
This model is rated for maximum flow rates of up to 198 litres per second.
Under typical industrial and HVAC standard conditions, the nominal cooling capacity of this model ranges approximately from 1,200 kW to 2,100 kW.
Why Does Cooling Capacity Vary?
- Wet Bulb Temperature (Ambient Air): The cooler and drier the surrounding air, the more water can evaporate, thus increasing cooling capacity.
- Water Temperatures: Performance changes significantly depending on the hot water inlet temperature (e.g., 35°C) and the cold water outlet temperature (e.g., 29°C).
- Air Volume Flow: According to BAC technical data, the S15E 1018-10 LE actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
- If the airflow is reduced by a frequency converter (e.g., during night mode or in winter), the cooling capacity decreases in a controlled manner.
- Approach: This is the most important thermodynamic factor – the difference between the desired cold water temperature and the wet bulb temperature set by physics. The closer the cold water approaches the wet bulb, the less kW the tower can achieve.
Technical Data:
Fan & Air Data
- Air volume flow: 60.0 m³/s (induced draft)
- Fan motors: 3 x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
- Water Inlet (Fluid Inlet): 1 x DN 250 (nominal diameter ND 250 mm)
- Water Outlet (Fluid Outlet): 1 x DN 300 (ND 300 mm)
- Make-up Water Connection: 1 x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2008
550 Iklan online
Kirim permintaan
Telepon & Faks
+49 2862 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Niedźwiedź
10.363 km
Unit kompresor
BITZERHSK 6461-60
BITZERHSK 6461-60
Iklan kecil
Nysa
10.551 km
Unit RIVACOLD + evaporator
RIVACOLDRV4B0905 + RX50334
RIVACOLDRV4B0905 + RX50334
Iklan kecil
Łęczna
10.162 km
Pendingin/pompa panas
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
Iklan kecil
Niedźwiedź
10.363 km
Unit kompresor
BITZER4NCS-12.2Y-40-40P (x4)
BITZER4NCS-12.2Y-40-40P (x4)
Iklan kecil
Niedźwiedź
10.363 km
Kondensor
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
Iklan kecil
Hillegom
11.392 km
Pendingin kering
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
Iklan kecil
Rumania
11.248 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
Iklan kecil
Lanaken
11.359 km
Penukar panas pelat
SondexSF160
SondexSF160
Iklan kecil
Enschede
11.236 km
Mesin Cetak Injeksi
ENGELE-VICTORY 765H/170W/400 COMBI
ENGELE-VICTORY 765H/170W/400 COMBI
Iklan kecil
Ecquevilly
11.672 km
Unit pending
Copeland EmersonZXLE 50
Copeland EmersonZXLE 50
Iklan Anda telah berhasil dihapus
Terjadi kesalahan