Generator daruratBGG - Deutschland
EPS-C40 770S
Generator darurat
BGG - Deutschland
EPS-C40 770S
harga tetap ditambah PPN
€194.000
tahun pembuatan
2023
Kondisi
Baru
Lokasi
Nüziders 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Generator darurat
- pabrikan:
- BGG - Deutschland
- Model:
- EPS-C40 770S
- Nomor mesin:
- 221055-1
- tahun pembuatan:
- 2023
- Kondisi:
- baru
- fungsi:
- berfungsi sepenuhnya
Harga & Lokasi
harga tetap ditambah PPN
€194.000
- Lokasi:
- Kuhbrückweg 3, 6714 Nüziders, AT
Hubungi
Rincian teknis
- Jenis arus masuk:
- AC (pendingin udara)
- Tegangan masuk:
- 400 V
- Jenis pendinginan:
- air
- Lebar total:
- 2.430 mm
- Panjang total:
- 12.080 mm
- Tinggi total:
- 2.880 mm
- Bahan bakar:
- diesel
- Berat keseluruhan:
- 18.000 kg
- Daya semu kontinu:
- 770 kVA
- Daya kontinu:
- 616 kW (837,53 hp)
- Kecepatan rotasi (maks.):
- 1.500 rpm
- Kapasitas silinder:
- 16.400 cm³
- Kapasitas tangki bahan bakar:
- 9.000 l
- Kapasitas tangki:
- 9.000 l
- Daya:
- 616 kW (837,53 hp)
- Daya nominal (semu):
- 770 kVA
- Frekuensi input:
- 50 Hz
- Perlengkapan:
- dokumentasi / manual, kecepatan rotasi dapat diubah tanpa batas
Rincian penawaran
- ID iklan:
- A18494271
- pembaruan:
- terakhir pada 23.06.2025
Deskripsi
EPS-C40 770S - 72h Container Emergency Power Supply System:
IMMEDIATELY AVAILABLE!!!!
GT770S 770 700 Scania DC16 078A 02 43 400/230V 50Hz-LS
Rated Power PRP: 700.0 kVA, 560.0 kW cos Phi = 0.8
Rated Power LTP: 770.0 kVA, 616.0 kW cos Phi = 0.8
Reference conditions according to DIN ISO 8528
Speed: 1500 rpm.
Design: Stationary
Engine:
Scania DC16 078A 02 43, four-stroke diesel engine, liquid-cooled, crankcase ventilation
re-routed into engine block, fuel system with pre-filter, filter and water separator,
combustion air filter with vacuum indicator, fuel hoses for connecting the
supply and return lines with flexible couplings. Electric starter system,
engine shutdown system, and electronically controlled speed governor.
Rated output: 596.0 kW
Rated speed: 1500 rpm.
Cylinders: 8-cylinder V
Displacement: 16400 cc
Leroy Somer LSA 49.3 M6
4-pole three-phase synchronous generator
Continuous rating: 730.0 kVA at 40°C
Rated voltage: 400V
Rated frequency: 50Hz
Manual oil change pump from 700 kVA
Hand pump for draining the engine oil pan.
Electric engine preheater 1000W up to 700 kVA 1.00 pcs.
The preheated coolant circulates in the primary cooling circuit of the engine
by convection. Connected with flexible coolant hoses to the engine's internal
Fpjdpfx Asvyp H Uedqon
cooling circuit, equipped with shut-off valves for isolation during servicing.
Coolant circulation pump
guarantees reliable preheating of the engine.
Walls and roof made of profiled sheet steel. Derusting and cleaning
performed by sandblasting the welded structure. The container is coated internally and externally
with seawater-resistant primers and paints.
40" HC High Cube Soundproof Container
Container ISO 1496-1 for power generation units, external dimensions per ISO 668.
The wall and roof surfaces are insulated with self-extinguishing, oil- and water-resistant
sound-absorbing material and clad with fiberglass mat and electro-galvanized, coated perforated sheet cassettes.
The exhaust silencer is accommodated in a separate compartment within the container.
Radiant heat is reliably discharged vertically with the cooling air stream from the auxiliary radiator.
Air intake openings are integrated into the wall surfaces, exhaust outlet in the roof.
The silencer's exhaust outlet is protected with a rain cap against water ingress.
One end face is equipped with a double-leaf door with circumferential seal,
serving as inspection opening.
Side personnel doors with emergency release and all-round sealing provide access for
maintenance operations.
The silencer and discharge compartment is also equipped with an access door.
The system is operated from outside.
Control and display instruments are visible through a viewing window
when the control panel door is closed.
Emergency stop button is securely installed in a recessed housing niche to prevent damage.
Cable entry is possible at the side or through the container floor. The
floor duct is prepared for annular space seals DN 150.
40" Container bunded collection tray according to WHG
Oil-tight welded checker plate floor with circumferential upstand min. 50 mm
And much more ....
Special feature: PARALLEL GRID OPERATION possible!!!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
IMMEDIATELY AVAILABLE!!!!
GT770S 770 700 Scania DC16 078A 02 43 400/230V 50Hz-LS
Rated Power PRP: 700.0 kVA, 560.0 kW cos Phi = 0.8
Rated Power LTP: 770.0 kVA, 616.0 kW cos Phi = 0.8
Reference conditions according to DIN ISO 8528
Speed: 1500 rpm.
Design: Stationary
Engine:
Scania DC16 078A 02 43, four-stroke diesel engine, liquid-cooled, crankcase ventilation
re-routed into engine block, fuel system with pre-filter, filter and water separator,
combustion air filter with vacuum indicator, fuel hoses for connecting the
supply and return lines with flexible couplings. Electric starter system,
engine shutdown system, and electronically controlled speed governor.
Rated output: 596.0 kW
Rated speed: 1500 rpm.
Cylinders: 8-cylinder V
Displacement: 16400 cc
Leroy Somer LSA 49.3 M6
4-pole three-phase synchronous generator
Continuous rating: 730.0 kVA at 40°C
Rated voltage: 400V
Rated frequency: 50Hz
Manual oil change pump from 700 kVA
Hand pump for draining the engine oil pan.
Electric engine preheater 1000W up to 700 kVA 1.00 pcs.
The preheated coolant circulates in the primary cooling circuit of the engine
by convection. Connected with flexible coolant hoses to the engine's internal
Fpjdpfx Asvyp H Uedqon
cooling circuit, equipped with shut-off valves for isolation during servicing.
Coolant circulation pump
guarantees reliable preheating of the engine.
Walls and roof made of profiled sheet steel. Derusting and cleaning
performed by sandblasting the welded structure. The container is coated internally and externally
with seawater-resistant primers and paints.
40" HC High Cube Soundproof Container
Container ISO 1496-1 for power generation units, external dimensions per ISO 668.
The wall and roof surfaces are insulated with self-extinguishing, oil- and water-resistant
sound-absorbing material and clad with fiberglass mat and electro-galvanized, coated perforated sheet cassettes.
The exhaust silencer is accommodated in a separate compartment within the container.
Radiant heat is reliably discharged vertically with the cooling air stream from the auxiliary radiator.
Air intake openings are integrated into the wall surfaces, exhaust outlet in the roof.
The silencer's exhaust outlet is protected with a rain cap against water ingress.
One end face is equipped with a double-leaf door with circumferential seal,
serving as inspection opening.
Side personnel doors with emergency release and all-round sealing provide access for
maintenance operations.
The silencer and discharge compartment is also equipped with an access door.
The system is operated from outside.
Control and display instruments are visible through a viewing window
when the control panel door is closed.
Emergency stop button is securely installed in a recessed housing niche to prevent damage.
Cable entry is possible at the side or through the container floor. The
floor duct is prepared for annular space seals DN 150.
40" Container bunded collection tray according to WHG
Oil-tight welded checker plate floor with circumferential upstand min. 50 mm
And much more ....
Special feature: PARALLEL GRID OPERATION possible!!!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2025
Kirim permintaan
Telepon & Faks
+43 5552 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan