Mesin pencuci bronkoskop profesionalBHT
INNOVA E3
Mesin pencuci bronkoskop profesional
BHT
INNOVA E3
VB ditambah PPN
€6.640
Tahun pembuatan
2013
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Mesin pencuci bronkoskop profesional
- Pabrikan:
- BHT
- Model:
- INNOVA E3
- Tahun pembuatan:
- 2013
- Kondisi:
- baik (bekas)
Harga & Lokasi
VB ditambah PPN
€6.640
- Lokasi:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A7725170
- Nomor referensi:
- 25755
- Pembaruan:
- terakhir pada 06.08.2025
Deskripsi
BHT INNOVA E3 Professional Bronchoscope Washer-Disinfector
INNOVA – Professional Endoscope Washer-Disinfector for Medical Practices and Small Clinics
The INNOVA™ E3s is the world’s best-selling BHT endoscope washer-disinfector. This model is compact yet offers high throughput for endoscopes or bronchoscopes. Depending on the reprocessing method, up to 10 to 20 endoscope cycles per day are possible, making it the ideal solution for private practitioners and small clinics that prioritize hygiene safety, efficiency, and reliability.
Reliability and optimum cleanliness with every cycle:
- Complies with DIN EN ISO 15883-1/-4 and RKI guidelines, including numerous features, such as thermal self-disinfection at 90°C in accordance with DIN EN ISO 15883-4, 4.8.1.
- Flexible combination with an additional INNOVA® E2 or E3 for 30 to 40 cycles per day.
- Compatible with both glutaraldehyde and peracetic acid from various suppliers.
- Suitable for standard endoscopes from Fuji, Olympus, Pentax, Storz, and Wolf.
- Single channel connection or patented pressure chamber system available.
- Option for thermal reprocessing, e.g., multiple-use biopsy forceps, polypectomy snares, etc.
- Thermal disinfection of final rinse water as recommended by the RKI for the DH version.
- Reliable documentation and traceability via batch control, including user and endoscope identification with barcode scanner.
- Data output via printer, data logger, or IT interface. Easy integration into existing IT systems.
Iiodpfx Ajin Edweahek
Endoscope Capacity: For 2 endoscopes or 4 ENT scopes
Hygiene Concept: Hygienic workflow, single-door design
Channel Connection System: Single channel or patented pressure chamber system possible
Single Channel Monitoring (CMS): No
Chemicals – Glutaraldehyde / Peracetic Acid: Both possible: DH version (with boiler, for glutaraldehyde) or DC version (filter solution, for glutaraldehyde or peracetic acid)
Documentation and Integration: Yes, standard interface for printer/data logger. Printer included as standard. Optional scanner/IT interface.
Thermal Instrument Reprocessing at 90°C: Available with additional equipment
Electrical Installation: 3-phase 400 V / 50 Hz AC+N+PE. Connected load: 11 kW. Fuse protection: 3 x 20 A
Year of Manufacture: 19.01.2013
Item condition: used
More items – new and used – in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
INNOVA – Professional Endoscope Washer-Disinfector for Medical Practices and Small Clinics
The INNOVA™ E3s is the world’s best-selling BHT endoscope washer-disinfector. This model is compact yet offers high throughput for endoscopes or bronchoscopes. Depending on the reprocessing method, up to 10 to 20 endoscope cycles per day are possible, making it the ideal solution for private practitioners and small clinics that prioritize hygiene safety, efficiency, and reliability.
Reliability and optimum cleanliness with every cycle:
- Complies with DIN EN ISO 15883-1/-4 and RKI guidelines, including numerous features, such as thermal self-disinfection at 90°C in accordance with DIN EN ISO 15883-4, 4.8.1.
- Flexible combination with an additional INNOVA® E2 or E3 for 30 to 40 cycles per day.
- Compatible with both glutaraldehyde and peracetic acid from various suppliers.
- Suitable for standard endoscopes from Fuji, Olympus, Pentax, Storz, and Wolf.
- Single channel connection or patented pressure chamber system available.
- Option for thermal reprocessing, e.g., multiple-use biopsy forceps, polypectomy snares, etc.
- Thermal disinfection of final rinse water as recommended by the RKI for the DH version.
- Reliable documentation and traceability via batch control, including user and endoscope identification with barcode scanner.
- Data output via printer, data logger, or IT interface. Easy integration into existing IT systems.
Iiodpfx Ajin Edweahek
Endoscope Capacity: For 2 endoscopes or 4 ENT scopes
Hygiene Concept: Hygienic workflow, single-door design
Channel Connection System: Single channel or patented pressure chamber system possible
Single Channel Monitoring (CMS): No
Chemicals – Glutaraldehyde / Peracetic Acid: Both possible: DH version (with boiler, for glutaraldehyde) or DC version (filter solution, for glutaraldehyde or peracetic acid)
Documentation and Integration: Yes, standard interface for printer/data logger. Printer included as standard. Optional scanner/IT interface.
Thermal Instrument Reprocessing at 90°C: Available with additional equipment
Electrical Installation: 3-phase 400 V / 50 Hz AC+N+PE. Connected load: 11 kW. Fuse protection: 3 x 20 A
Year of Manufacture: 19.01.2013
Item condition: used
More items – new and used – in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2862 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan






















