Deskripsi
en-Hach DR 3800 VIS Spectrophotometer
The DR 3800 is a VIS spectrophotometer covering a wavelength range from 320 to 1100 nm. The unit comes with a comprehensive suite of application programs and supports multiple languages. The DR 3800 spectrophotometer includes the following
Programs and Operating Modes:
Stored programs (pre-installed tests), barcode programs, user-defined programs, favorites, single wavelength, multi-wavelength, wavelength scan, and time scan.
The DR 3800 spectrophotometer performs digital measurements in the units of concentration, absorbance (extinction), or percent transmittance.
When choosing a user-generated or programmed method, a structured menu navigation and prompts guide the operator through the test procedure. This menu system can also generate reports, statistical evaluations of generated calibration curves, and equipment diagnostic reports.
Display modes: Transmittance (%), Absorbance (Extinction), and Concentration
Light source: Halogen lamp
Wavelength range: 320–1100 nm
Wavelength accuracy: ± 1.5 nm (wavelength range 340–900 nm)
Wavelength reproducibility: 0.1 nm
Wavelength resolution: 1 nm
Wavelength calibration: automatic
Wavelength selection: automatic, depending on the selected method
Scan speed: = 12 nm/s (in 1-nm steps)
Spectral bandwidth: 5 nm
Photometric measuring range: ± 3.0 Ext (wavelength range 340–900 nm)
Photometric accuracy: 5 mExt at 0.0–0.5 Ext; 1% at 0.50–2.0 Ext
Stray light: < 0.1% T at 340 nm with NaNO₂
Data memory: 1000 measurements (result, date, time, sample ID, user ID)
User programs: 50
Dimensions of measuring unit and environmental conditions: Width 368 mm; Height 144 mm; Depth 359 mm; Weight 6.4 kg
Ambient conditions (operation): 10–40°C, max. 80% relative humidity (non-condensing)
Ambient conditions (storage): -40–60°C, max. 80% relative humidity (non-condensing)
Ijdpfx Aeiuzvxob Isa
External power supply: 100-240 V / 50-60 Hz (input); 15 V / 30 VA (output)
Interfaces: Only use shielded cables (max. 3 m length). 1 x USB Type A; 1 x USB Type B
Housing protection rating: IP3X
Device classification: Device: Class III; System: Class II
Item condition: used
More items – new and used – can be found in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
The DR 3800 is a VIS spectrophotometer covering a wavelength range from 320 to 1100 nm. The unit comes with a comprehensive suite of application programs and supports multiple languages. The DR 3800 spectrophotometer includes the following
Programs and Operating Modes:
Stored programs (pre-installed tests), barcode programs, user-defined programs, favorites, single wavelength, multi-wavelength, wavelength scan, and time scan.
The DR 3800 spectrophotometer performs digital measurements in the units of concentration, absorbance (extinction), or percent transmittance.
When choosing a user-generated or programmed method, a structured menu navigation and prompts guide the operator through the test procedure. This menu system can also generate reports, statistical evaluations of generated calibration curves, and equipment diagnostic reports.
Display modes: Transmittance (%), Absorbance (Extinction), and Concentration
Light source: Halogen lamp
Wavelength range: 320–1100 nm
Wavelength accuracy: ± 1.5 nm (wavelength range 340–900 nm)
Wavelength reproducibility: 0.1 nm
Wavelength resolution: 1 nm
Wavelength calibration: automatic
Wavelength selection: automatic, depending on the selected method
Scan speed: = 12 nm/s (in 1-nm steps)
Spectral bandwidth: 5 nm
Photometric measuring range: ± 3.0 Ext (wavelength range 340–900 nm)
Photometric accuracy: 5 mExt at 0.0–0.5 Ext; 1% at 0.50–2.0 Ext
Stray light: < 0.1% T at 340 nm with NaNO₂
Data memory: 1000 measurements (result, date, time, sample ID, user ID)
User programs: 50
Dimensions of measuring unit and environmental conditions: Width 368 mm; Height 144 mm; Depth 359 mm; Weight 6.4 kg
Ambient conditions (operation): 10–40°C, max. 80% relative humidity (non-condensing)
Ambient conditions (storage): -40–60°C, max. 80% relative humidity (non-condensing)
Ijdpfx Aeiuzvxob Isa
External power supply: 100-240 V / 50-60 Hz (input); 15 V / 30 VA (output)
Interfaces: Only use shielded cables (max. 3 m length). 1 x USB Type A; 1 x USB Type B
Housing protection rating: IP3X
Device classification: Device: Class III; System: Class II
Item condition: used
More items – new and used – can be found in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2862 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan