Unit monoblok tunggang negatif
L19130B JKS

harga tetap ditambah PPN
€4.844
Kondisi
Baru
Lokasi
Vincennes Prancis
Unit monoblok tunggang negatif L19130B JKS
Unit monoblok tunggang negatif L19130B JKS
Unit monoblok tunggang negatif L19130B JKS
Unit monoblok tunggang negatif L19130B JKS
Unit monoblok tunggang negatif L19130B JKS
more Images
L19130B JKS
L19130B JKS
L19130B JKS
L19130B JKS
L19130B JKS
Gambar menunjukkan
Tampilkan peta

Data mesin

Nama mesin:
Unit monoblok tunggang negatif
Pabrikan:
L19130B
Model:
JKS
Kondisi:
baru

Harga & Lokasi

harga tetap ditambah PPN
€4.844
Lokasi:
Rue de Fontenay 110, 94300 Vincennes, France Prancis
Hubungi

Rincian penawaran

ID iklan:
A20495340
Pembaruan:
terakhir pada 10.11.2025

Deskripsi

- External dimensions (LxDxH): 644x930x863 mm
- Application range: -18 ÷ -22
- Evaporation temperature: -30°C
- Condensation temperature: +40°C
- Cold room temperature: -20°C
- Ambient temperature: 32°C
- Defrosting: Hot gas
- Power supply: 230 V / 1+N ph / 50 Hz
- Maximum absorbed current: 13.2 A
- Maximum absorbed power: 2.8 kW
- Rated absorbed power: 110 W
- Refrigerant: R452A
- Power: 1,318 W
- Rated power: 1.9 HP
- Compressor type: E
- Fin spacing: 2.5 mm
- Fans: 1 x ø300 mm
- Air flow rate: 1,000 m³/h
- Air throw: 6
- Weight: 89 kg
- Volume: 0.80 m³
- Hermetic compressor
- Air-cooled condenser
- Galvanised steel housing
- Automatic reset high and low pressure switch
- Axial fan
- Hot gas defrost solenoid valve
- Condensate drain trap
- Condensate drain heater (BT models only)
- Ambient temperature sensor
- End of defrost sensor
- Condensation control sensor
- Power cable for door heater
- Micro-door connection cable
- Digital display with temperature indication
- Operating status display:
Dwjdoxvr Upopfx Afnjd
- Cooling/defrost
- Evaporator fans
- Active alarm
- Programming keys
- Manual defrost button
- Audible alarm
- Low and high temperature alarm
- High temperature alarm for dirty condenser
- Low condenser temperature alarm
- Door open alarm
- High and low pressure alarm
- End of defrost alarm if duration exceeds maximum
- Faulty temperature sensor alarm
- Faulty condensation control sensor alarm
- Evaporating temperature at -10°C for TN
- Condensation temperature at +40°C for TN
- Evaporation temperature at -30°C for BT
- Condensation temperature at +40°C for BT

Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.

Penyedia

Terdaftar sejak: 2025

198 Iklan online

Hubungi

Kirim permintaan

Tanahus 
Jerman
Austria
Swiss
Amerika Serikat
Britania Raya
Prancis
Belgia
Spanyol
Meksiko
Italia
Belanda
Polandia
Federasi Rusia
Belarus (Republik Belarus)
Ukraina
Estonia
Turki
Selandia Baru
Irlandia
Republik Ceko
Denmark
Finlandia
Swedia
Norwegia
Luksemburg
Yunani
Lituania
Latvia
Islandia
Portugal
Brasil
Venezuela
Argentina
Hungaria
Slovakia
Rumania
Moldova
Slovenia
Serbia
Montenegro
Albania
Kroasia
Bulgaria
Makedonia Utara
Bosnia dan Herzegovina
Israel
Mesir
Maroko
India
Indonesia
Korea Selatan
Jepang
Thailand
Malaysia
Vietnam
China
Taiwan
Iran
Bangladesh
Catatan: Permintaan Anda akan diteruskan ke semua penjual di kategori mesin. Dengan ini, Anda dapat menerima sangat banyak penawaran.
Permintaan tidak dapat dikirim. Silakan coba lagi nanti.

Telepon & Faks

+33 1 84 ... iklan