Analisis sistem acridinium esterSiemens
Advia Centaur XP
Analisis sistem acridinium ester
Siemens
Advia Centaur XP
VB ditambah PPN
€6.720
Tahun pembuatan
2010
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Analisis sistem acridinium ester
- Pabrikan:
- Siemens
- Model:
- Advia Centaur XP
- Tahun pembuatan:
- 2010
- Kondisi:
- baik (bekas)
Harga & Lokasi
VB ditambah PPN
€6.720
- Lokasi:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A6779482
- Nomor referensi:
- 24568
- Pembaruan:
- terakhir pada 28.11.2024
Deskripsi
Siemens Advia Centaur XP Analysis System
With Siemens Healthineers Service and Maintenance until 02/2022
Modern AE Immunoassay Technology
Meets clinical requirements through acridinium ester (AE) technology, providing the flexibility and sensitivity needed for new and innovative assays.
Comprehensive diagnostic evaluation of a wide range of conditions with a test menu featuring over 70 different assays.
Simplified inventory management and reduced costs due to the use of the same ready-to-use reagents across all ADVIA Centaur analysis systems.
Simplified Operation, Continuous Workflow
All samples, reagents, and consumables can be loaded and unloaded during ongoing operation.
Easier training and operation thanks to an intuitive, icon-based user interface.
Less operator intervention required, as daily maintenance is minimal and there is no need for monthly cleaning or daily system start-up.
New and updated test definitions can be loaded by users via simple scanning of the 2D barcodes included in the instructions for use.
Consistent, Predictable Turnaround Time (TAT) and Accuracy
Up to 240 tests/hour for rapid turnaround time, even during peak periods.
Ltjdpfx Aashr Rw Iehoa
Fast prioritization of emergency samples at any time via a dedicated STAT port.
Single-use pipette tips prevent carryover and sample contamination.
Automatic repeat and confirmation testing of reactive hepatitis B surface antigen samples using Siemens Healthineers SMART algorithms.
Direct Connectivity
Adaptable to varying sample volumes with simple integration into Aptio and VersaCell® X3 automation solutions.
Efficient operation enabled by diagnostics IT, including the CentraLink® data management system, Atellica Process Manager, and Smart Remote Services for Diagnostics.
Direct pipetting from the automation solution using Point-in-Space technology.
Shorter processing times for emergency samples, as the dedicated STAT port enables front-loading of STAT specimens even when connected to an automation solution.
Technical Specifications
Product Specifications
System type: Random-access immunoassay system
Throughput: Up to 240 tests per hour
Time to First Result
18 minutes, additional results at 15-second intervals (method-dependent)
Onboard Method Capacity: 30 test methods
Indication Groups
Allergy, anemia, diabetes, fertility, hepatitis, HIV, immunosuppressants, infectious serology, cardiology, bone metabolism, liver fibrosis, adrenal function, oncology, thyroid diseases, sepsis, therapeutic drug monitoring (TDM)
Continuous Operation
Samples and consumables can be loaded and unloaded at any time during running operation, including sample racks, STAT samples, reagents, supplemental reagents, reaction cuvettes, sample tips, calibrators, controls, wash solutions, water, and waste.
Samples and Sample Management: Sample Tubes
3 ml, 5 ml, 7 ml, and 10 ml tubes; 1 ml and 2 ml secondary containers; microtubes
Sample Feed
Universal rack with 5 positions for various tube types, total capacity 180 samples; loading and unloading possible during operation.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
With Siemens Healthineers Service and Maintenance until 02/2022
Modern AE Immunoassay Technology
Meets clinical requirements through acridinium ester (AE) technology, providing the flexibility and sensitivity needed for new and innovative assays.
Comprehensive diagnostic evaluation of a wide range of conditions with a test menu featuring over 70 different assays.
Simplified inventory management and reduced costs due to the use of the same ready-to-use reagents across all ADVIA Centaur analysis systems.
Simplified Operation, Continuous Workflow
All samples, reagents, and consumables can be loaded and unloaded during ongoing operation.
Easier training and operation thanks to an intuitive, icon-based user interface.
Less operator intervention required, as daily maintenance is minimal and there is no need for monthly cleaning or daily system start-up.
New and updated test definitions can be loaded by users via simple scanning of the 2D barcodes included in the instructions for use.
Consistent, Predictable Turnaround Time (TAT) and Accuracy
Up to 240 tests/hour for rapid turnaround time, even during peak periods.
Ltjdpfx Aashr Rw Iehoa
Fast prioritization of emergency samples at any time via a dedicated STAT port.
Single-use pipette tips prevent carryover and sample contamination.
Automatic repeat and confirmation testing of reactive hepatitis B surface antigen samples using Siemens Healthineers SMART algorithms.
Direct Connectivity
Adaptable to varying sample volumes with simple integration into Aptio and VersaCell® X3 automation solutions.
Efficient operation enabled by diagnostics IT, including the CentraLink® data management system, Atellica Process Manager, and Smart Remote Services for Diagnostics.
Direct pipetting from the automation solution using Point-in-Space technology.
Shorter processing times for emergency samples, as the dedicated STAT port enables front-loading of STAT specimens even when connected to an automation solution.
Technical Specifications
Product Specifications
System type: Random-access immunoassay system
Throughput: Up to 240 tests per hour
Time to First Result
18 minutes, additional results at 15-second intervals (method-dependent)
Onboard Method Capacity: 30 test methods
Indication Groups
Allergy, anemia, diabetes, fertility, hepatitis, HIV, immunosuppressants, infectious serology, cardiology, bone metabolism, liver fibrosis, adrenal function, oncology, thyroid diseases, sepsis, therapeutic drug monitoring (TDM)
Continuous Operation
Samples and consumables can be loaded and unloaded at any time during running operation, including sample racks, STAT samples, reagents, supplemental reagents, reaction cuvettes, sample tips, calibrators, controls, wash solutions, water, and waste.
Samples and Sample Management: Sample Tubes
3 ml, 5 ml, 7 ml, and 10 ml tubes; 1 ml and 2 ml secondary containers; microtubes
Sample Feed
Universal rack with 5 positions for various tube types, total capacity 180 samples; loading and unloading possible during operation.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2008
Kirim permintaan
Telepon & Faks
+49 2862 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Borken
11.254 km
Alat analisis imunodiagnostik
DiasorinLiaison Typ 2229
DiasorinLiaison Typ 2229
Iklan kecil
Győr
10.553 km
Penganalisis Kimia Klinis
Instrumentation LaboratoryILab Aries
Instrumentation LaboratoryILab Aries
Iklan Anda telah berhasil dihapus
Terjadi kesalahan