CO2 Incubator - CALIBRATEDThermo Fisher Scientific
3311
CO2 Incubator - CALIBRATED
Thermo Fisher Scientific
3311
EXW Harga tetap ditambah PPN
€1.500
Tahun pembuatan
2010
Kondisi
Bekas
(berfungsi sepenuhnya)
Lokasi
Töltéstava 

Data dasar
- Nama mesin:
- CO2 Incubator - CALIBRATED
- Pabrikan:
- Thermo Fisher Scientific
- Model:
- 3311
- Tahun pembuatan:
- 2010
- Kondisi:
- siap digunakan (bekas)
- Fungsi:
- berfungsi sepenuhnya
Harga & Lokasi
EXW Harga tetap ditambah PPN
€1.500
- Lokasi:
- 0184/3. Hrsz, 9086 Töltéstava, Hungary

Hubungi
Rincian penawaran
- ID iklan:
- A23088001
- Pembaruan:
- terakhir pada 20.10.2026
Deskripsi
We have two units in stock. Price is for one unit only.
Carry out high-volume culturing with a high-level of contamination control with these stackable Thermo Scientific Forma Steri-Cult CO2 Incubators. This incubator combines the most advanced components available into a single incubator: CO2 sensor, precise microprocessor controls, active humidity control, HEPA air filtration and high-temperature decontamination capability.
Integral 140°C high-temperature sterilization function, 14 hr duration.
Optimized airflow system will not interfere with samples or incubator function.
In-chamber HEPA air filtration continuously removes particulates for Class 100 quality conditions.
On-demand 140°C sterilization cycle eliminates contamination from internal surfaces.
Audible alarm activates if outer door is opened during the cycle or if temperature reaches 60°C or greater.
Access code prevents accidental initiation of the cycle.
Alphanumeric messaging center clearly displays temperature, CO2 and RH.
Audible/visual alarms with silence button.
Setpoints for temperature, overtemperature, CO2 and RH.
Dodpfj Aaw Rbsx Aavocp
Configurable audible ON/OFF, access code, HEPA filter change reminder, remote alarm contacts, tracking low temp and high and low CO2 and RH alarms.
Temperature Range: Ambient +5°C to 50°C
Relative Humidity: 95%, controllable
Humidity Source: External humidity reservoir
CO2 Concentration Range: 0 to 20%
CO2 Sensor Technology: IR Sensor
Capacity: 322.8 L
Chamber Material: Polished Stainless Steel
Interior Dimensions (DxWxH): 523 x 732 x 838 mm
Dimensions (DxWxH): 686 x 1092 x 1002 mm
Good working condition. Please check out our other listings as well.
Carry out high-volume culturing with a high-level of contamination control with these stackable Thermo Scientific Forma Steri-Cult CO2 Incubators. This incubator combines the most advanced components available into a single incubator: CO2 sensor, precise microprocessor controls, active humidity control, HEPA air filtration and high-temperature decontamination capability.
Integral 140°C high-temperature sterilization function, 14 hr duration.
Optimized airflow system will not interfere with samples or incubator function.
In-chamber HEPA air filtration continuously removes particulates for Class 100 quality conditions.
On-demand 140°C sterilization cycle eliminates contamination from internal surfaces.
Audible alarm activates if outer door is opened during the cycle or if temperature reaches 60°C or greater.
Access code prevents accidental initiation of the cycle.
Alphanumeric messaging center clearly displays temperature, CO2 and RH.
Audible/visual alarms with silence button.
Setpoints for temperature, overtemperature, CO2 and RH.
Dodpfj Aaw Rbsx Aavocp
Configurable audible ON/OFF, access code, HEPA filter change reminder, remote alarm contacts, tracking low temp and high and low CO2 and RH alarms.
Temperature Range: Ambient +5°C to 50°C
Relative Humidity: 95%, controllable
Humidity Source: External humidity reservoir
CO2 Concentration Range: 0 to 20%
CO2 Sensor Technology: IR Sensor
Capacity: 322.8 L
Chamber Material: Polished Stainless Steel
Interior Dimensions (DxWxH): 523 x 732 x 838 mm
Dimensions (DxWxH): 686 x 1092 x 1002 mm
Good working condition. Please check out our other listings as well.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2020
272 Iklan online
Kirim permintaan
Telepon & Faks
+36 62 99... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan










