Deskripsi
These scraped surface heat exchangers can be used for the heating process of various products, such as tomato paste, puddings, margarines, oils, mayonnaise, etc. We have fully refurbished these units, including internal seals, rings, sandblasting, painting, new stainless steel frames, new control system, and motor testing and maintenance.
TECHNICAL DETAILS OF THE VOTATOR:
* Manufacturer: A. Johnson & Co London
* Year of refurbishment: 2025
* Quantity: 5 units
* Diameter: 6 inches
* Metals: 316 grade stainless steel
* Application: Horizontal type
SPECIFICATIONS:
* Chamber dimensions: 6" diameter stainless steel chamber
* Length: 6'
* 1 1/2" between end plates
* Rotating center: 4 3/4" diameter stainless steel
* Equipped with two PTFE scraper blades
* Drive: 11 kW motor drives
* Speed: 1470 rpm (via V-belt reduction)
* Reducer: Results in a shaft speed of approximately 367 rpm
AVAILABILITY:
* Location: In stock
* Available: Immediately
Kdodpfxjxxg T Es Aayew
GENERAL FORMULA FOR CAPACITY ESTIMATION:
For a VOTATOR, the capacity can be roughly estimated using the following formula:
[ \text{Capacity} = \text{Chamber Volume} \times \text{Turnover Rate} ]
STEP 1: CALCULATE THE CHAMBER VOLUME
The volume of a cylindrical chamber can be calculated as follows:
[ V = \pi \times r^2 \times h ]
Where:
* ( r ) = radius (half of the diameter in inches),
* ( h ) = height (length of the chamber in inches).
Given:
* Diameter = 6 inches, thus radius ( r = \frac{6}{2} = 3 ) inches
* Length ( h = 6 \text{ ft} = 72 \text{ inches} )
Volume calculation:
[ V = \pi \times (3)^2 \times 72 \approx \pi \times 9 \times 72 \approx 2036.75 \text{ cubic inches} ]
To convert cubic inches to liters (since 1 cubic inch = 0.0163871 liters):
[ V \approx 2036.75 \times 0.0163871 \approx 33.39 \text{ liters} ]
STEP 2: ESTIMATE THE TURNOVER RATE
The turnover rate depends on the VOTATOR speed and how often the chamber's contents can be processed. At a shaft speed of approx. 367 rpm, you can estimate about 1 turnover per minute for a basic approximation.
FINAL CAPACITY ESTIMATION
Assuming 1 turnover per minute:
[ \text{Capacity} \approx 33.39 \text{ liters/min} ]
SUMMARY
The estimated capacity of each VOTATOR is approximately 33.39 liters per minute.
CAPACITY CALCULATION:
* Estimated capacity: 33.39 liters/minute
CONVERT TO LITERS PER HOUR:
[ \text{Capacity per hour} = 33.39 \text{ liters/min} \times 60 \text{ min/hour} ]
[ \text{Capacity per hour} \approx 2003.4 \text{ liters/hour} ]
SUMMARY
The estimated capacity of each VOTATOR is approximately 2003.4 liters per hour.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
TECHNICAL DETAILS OF THE VOTATOR:
* Manufacturer: A. Johnson & Co London
* Year of refurbishment: 2025
* Quantity: 5 units
* Diameter: 6 inches
* Metals: 316 grade stainless steel
* Application: Horizontal type
SPECIFICATIONS:
* Chamber dimensions: 6" diameter stainless steel chamber
* Length: 6'
* 1 1/2" between end plates
* Rotating center: 4 3/4" diameter stainless steel
* Equipped with two PTFE scraper blades
* Drive: 11 kW motor drives
* Speed: 1470 rpm (via V-belt reduction)
* Reducer: Results in a shaft speed of approximately 367 rpm
AVAILABILITY:
* Location: In stock
* Available: Immediately
Kdodpfxjxxg T Es Aayew
GENERAL FORMULA FOR CAPACITY ESTIMATION:
For a VOTATOR, the capacity can be roughly estimated using the following formula:
[ \text{Capacity} = \text{Chamber Volume} \times \text{Turnover Rate} ]
STEP 1: CALCULATE THE CHAMBER VOLUME
The volume of a cylindrical chamber can be calculated as follows:
[ V = \pi \times r^2 \times h ]
Where:
* ( r ) = radius (half of the diameter in inches),
* ( h ) = height (length of the chamber in inches).
Given:
* Diameter = 6 inches, thus radius ( r = \frac{6}{2} = 3 ) inches
* Length ( h = 6 \text{ ft} = 72 \text{ inches} )
Volume calculation:
[ V = \pi \times (3)^2 \times 72 \approx \pi \times 9 \times 72 \approx 2036.75 \text{ cubic inches} ]
To convert cubic inches to liters (since 1 cubic inch = 0.0163871 liters):
[ V \approx 2036.75 \times 0.0163871 \approx 33.39 \text{ liters} ]
STEP 2: ESTIMATE THE TURNOVER RATE
The turnover rate depends on the VOTATOR speed and how often the chamber's contents can be processed. At a shaft speed of approx. 367 rpm, you can estimate about 1 turnover per minute for a basic approximation.
FINAL CAPACITY ESTIMATION
Assuming 1 turnover per minute:
[ \text{Capacity} \approx 33.39 \text{ liters/min} ]
SUMMARY
The estimated capacity of each VOTATOR is approximately 33.39 liters per minute.
CAPACITY CALCULATION:
* Estimated capacity: 33.39 liters/minute
CONVERT TO LITERS PER HOUR:
[ \text{Capacity per hour} = 33.39 \text{ liters/min} \times 60 \text{ min/hour} ]
[ \text{Capacity per hour} \approx 2003.4 \text{ liters/hour} ]
SUMMARY
The estimated capacity of each VOTATOR is approximately 2003.4 liters per hour.