Pembangkit listrik dan panas gabunganagriKomp GmbH
BGA/NGA168
Pembangkit listrik dan panas gabungan
agriKomp GmbH
BGA/NGA168
Tahun pembuatan
2024
Kondisi
Baru
Lokasi
Merkendorf 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Pembangkit listrik dan panas gabungan
- Pabrikan:
- agriKomp GmbH
- Model:
- BGA/NGA168
- Tahun pembuatan:
- 2024
- Kondisi:
- baru
- Fungsi:
- berfungsi sepenuhnya
Harga & Lokasi
- Lokasi:
- Energiepark 2, 91732 Merkendorf, Deutschland

Hubungi
Rincian teknis
- Daya:
- 350 kW (475,87 hp)
Rincian penawaran
- ID iklan:
- A16761621
- Pembaruan:
- terakhir pada 09.09.2024
Deskripsi
Compact, high-efficiency combined heat and power plant (CHP) featuring a state-of-the-art SCANIA V8 lean-burn turbocharged 4-stroke gas Otto engine. The genset, gas pressure regulation section, mixture and engine water cooling circuit are mounted on a base frame for power and heat generation. Equipped with a high-quality synchronous generator (3 phase, 400V, 50Hz) for parallel grid operation and optimized heat extraction via plate heat exchanger for heating/process water with a temperature level of 85°C supply / 70°C return.
OPTIONAL: Fitted with a catalytic converter (optionally SCR system) for low-emission operation in accordance with MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET/CHP – Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output from engine at 180°C exhaust temperature: 334 kWth
Electrical/thermal ratio: 1.05
Engine type: V8
Displacement: 16 L
Thermal input – 100% load: 845 kWel
Gas consumption at 50% CH4: 169.1 Nm³/h
Dimensions (L x W x H): 4.1 x 1.5 x 2.1 m
Weight (dry): 4500 kg
The CHP unit is equipped with a control cabinet featuring a display for visualization of all relevant operating parameters, including a DSL modem for remote maintenance and external monitoring, as well as an interface for control power integration with the E2M energy pilot. The delivery also includes a grid starter for optimal starting speed, gas detector, smoke detector, emergency stop switch, and alarm beacon/horn.
All pipelines are made of stainless steel (V2A) and insulated where necessary. To ensure the engine remains warm, installed heat pumps are programmed to operate in a defined cycle, maintaining the desired temperature.
Bcedpfx Afst Uu Ezj Seu
An automatic gas shut-off valve for external mounting (outside the CHP installation room) is not included in the scope of delivery.
The CHP plant complies with the medium voltage guideline VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP housing and all operating fluids are not included in the supply scope.
The CHP can be supplied optionally in a container.
The entire genset is also available in a natural gas version.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
OPTIONAL: Fitted with a catalytic converter (optionally SCR system) for low-emission operation in accordance with MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET/CHP – Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output from engine at 180°C exhaust temperature: 334 kWth
Electrical/thermal ratio: 1.05
Engine type: V8
Displacement: 16 L
Thermal input – 100% load: 845 kWel
Gas consumption at 50% CH4: 169.1 Nm³/h
Dimensions (L x W x H): 4.1 x 1.5 x 2.1 m
Weight (dry): 4500 kg
The CHP unit is equipped with a control cabinet featuring a display for visualization of all relevant operating parameters, including a DSL modem for remote maintenance and external monitoring, as well as an interface for control power integration with the E2M energy pilot. The delivery also includes a grid starter for optimal starting speed, gas detector, smoke detector, emergency stop switch, and alarm beacon/horn.
All pipelines are made of stainless steel (V2A) and insulated where necessary. To ensure the engine remains warm, installed heat pumps are programmed to operate in a defined cycle, maintaining the desired temperature.
Bcedpfx Afst Uu Ezj Seu
An automatic gas shut-off valve for external mounting (outside the CHP installation room) is not included in the scope of delivery.
The CHP plant complies with the medium voltage guideline VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP housing and all operating fluids are not included in the supply scope.
The CHP can be supplied optionally in a container.
The entire genset is also available in a natural gas version.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2021
Kirim permintaan
Telepon & Faks
+49 9826 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Ystad
10.728 km
Thermoformer
ILPRATMF SPEEDYFORM
ILPRATMF SPEEDYFORM
Iklan kecil
Viersen
11.297 km
Pembangkit listrik dan panas gabungan
MWMETW 800 EG-CO-KA
MWMETW 800 EG-CO-KA
Iklan kecil
Rimini
10.985 km
Generator
ERCOLE MARELLI1312T
ERCOLE MARELLI1312T
Iklan kecil
Gusselby
10.583 km
Garis gergaji lengkap untuk kayu gelondongan besar
AKE,Söderhamns, Remill, Catech, Ari
AKE,Söderhamns, Remill, Catech, Ari
Iklan kecil
Bad Driburg
11.105 km
Penggulung peregangan orbital
Spinner 1000s
Spinner 1000s
Iklan kecil
Urk
11.312 km
Thermoformer
WebomaticAPS ML 7100
WebomaticAPS ML 7100
Iklan kecil
Roreto
11.347 km
UNLOADER (SINGLE-SANGKAR)
RBO (BIESSE Group)Tornado SC 1300
RBO (BIESSE Group)Tornado SC 1300
Iklan kecil
Bergkamen
11.202 km
Mini ekskavator
CASECX 26 C mit Klima
CASECX 26 C mit Klima
Iklan kecil
Jerman
10.886 km
Turbin uap
Nadrowski BielefeldC4DS-GVI
Nadrowski BielefeldC4DS-GVI
Iklan kecil
Forst
11.196 km
Tangki penyangga 100 m³, 3 bar, terisolasi
Iklan Anda telah berhasil dihapus
Terjadi kesalahan