Welding transformer, high-current transformer, transformer
for spot welding machines, projection welding machines, seam welding machines
ELREX type 3x ET70.0.G
Serial no.: Year of manufacture: approx. 1990
Consists of three water-cooled transformers with water-cooled rectifier block
Performance data:
Total output at 50% duty cycle: 210 kVA
Secondary voltage: 7 - 10.5 volts (adjustable in 4 steps via terminal clamps on the transformer)
Primary connection: 380 volts, 50 Hz (three-phase)
Consisting of three transformers - data per single transformer:
Output at 50% duty cycle: 70 kVA
Secondary voltage: 7 - 10.5 volts (adjustable in 4 steps via terminal clamps on the transformer)
Secondary current at 50% duty cycle: 6.7 kA
Primary connection: 380 volts, 50 Hz (two-phase)
Cooling water demand per transformer: 4 liters/min
Insulation class: F
- Water-cooled transformer
- Water-cooled rectifier block is mounted on the secondary side
Lhedpfx Ajdzp Txoahsr
- DC output connected via contact surfaces 50x50mm with M20x1.5mm threaded holes
- Temperature monitors on each rectifier element and each transformer coil
- Connection cable: 7-core, cross-section 50 mm², length approx. 6 m
Overall dimensions (W x H x D): 700 x 710 x 440 mm
Total weight: 480 kg
Good condition
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
for spot welding machines, projection welding machines, seam welding machines
ELREX type 3x ET70.0.G
Serial no.: Year of manufacture: approx. 1990
Consists of three water-cooled transformers with water-cooled rectifier block
Performance data:
Total output at 50% duty cycle: 210 kVA
Secondary voltage: 7 - 10.5 volts (adjustable in 4 steps via terminal clamps on the transformer)
Primary connection: 380 volts, 50 Hz (three-phase)
Consisting of three transformers - data per single transformer:
Output at 50% duty cycle: 70 kVA
Secondary voltage: 7 - 10.5 volts (adjustable in 4 steps via terminal clamps on the transformer)
Secondary current at 50% duty cycle: 6.7 kA
Primary connection: 380 volts, 50 Hz (two-phase)
Cooling water demand per transformer: 4 liters/min
Insulation class: F
- Water-cooled transformer
- Water-cooled rectifier block is mounted on the secondary side
Lhedpfx Ajdzp Txoahsr
- DC output connected via contact surfaces 50x50mm with M20x1.5mm threaded holes
- Temperature monitors on each rectifier element and each transformer coil
- Connection cable: 7-core, cross-section 50 mm², length approx. 6 m
Overall dimensions (W x H x D): 700 x 710 x 440 mm
Total weight: 480 kg
Good condition
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Kirim permintaan
Telepon & Faks
+49 5602 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Groenlo
11.263 km
Kompresor
Atlas CopcoXAS 58-7 Valid inspection, *Guarantee! Diesel, Vol
Atlas CopcoXAS 58-7 Valid inspection, *Guarantee! Diesel, Vol
Iklan kecil
Tatabánya
10.496 km
Transformator
Trockentransformator320 KVa 400V / 115 V (1562)
Trockentransformator320 KVa 400V / 115 V (1562)
Iklan kecil
Wiefelstede
11.134 km
Resistensi beban
Spohn BurkhardtGWR 132 S-R
Spohn BurkhardtGWR 132 S-R
Iklan Anda telah berhasil dihapus
Terjadi kesalahan