Espec
Type: PHP - J3
Technical Data:
Air-cooled
Temperature and humidity range: room temperature +10°C to +100°C / 40 to 98% relative humidity
Temperature fluctuation: ±0.3 K
Humidity fluctuation: ±2.5%
Internal volume: 398 liters
Dimensions:
Internal dimensions: width 600 mm x height 830 mm x depth 800 mm
Kfjdpfx Ajtzbzcjahoa
External dimensions: width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3-phase 50 Hz
Maximum current: 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climate test chamber
For your safety as a buyer, the following information applies!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Type: PHP - J3
Technical Data:
Air-cooled
Temperature and humidity range: room temperature +10°C to +100°C / 40 to 98% relative humidity
Temperature fluctuation: ±0.3 K
Humidity fluctuation: ±2.5%
Internal volume: 398 liters
Dimensions:
Internal dimensions: width 600 mm x height 830 mm x depth 800 mm
Kfjdpfx Ajtzbzcjahoa
External dimensions: width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3-phase 50 Hz
Maximum current: 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climate test chamber
For your safety as a buyer, the following information applies!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2012
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Borken
11.250 km
Suhu dan kelembapan ruang iklim
EspecPHP-J3 bis +100°C
EspecPHP-J3 bis +100°C
Iklan kecil
Raszyn
10.293 km
Pengisi tabung, mesin pengisi tabung
Jedlinski PackagingJTB-40
Jedlinski PackagingJTB-40
Iklan kecil
Radeberg
10.785 km
Pompa sentrifugal baja tahan karat Pompa baja tahan karat
KSBCPK-CM 250-315 / CPKN-C1 250-315
KSBCPK-CM 250-315 / CPKN-C1 250-315
Iklan kecil
Borken
11.250 km
Ruang iklim
VötschVC³ 4060
VötschVC³ 4060
Iklan kecil
Voerde
11.268 km
Pompa tekanan tinggi ABEL PC57.1
ABELPC57.1
ABELPC57.1
Iklan kecil
Borken
11.250 km
Ruang iklim kecil 60 liter dengan kelembapan
CTSC-40/60 -40 bis +180°C
CTSC-40/60 -40 bis +180°C
Iklan kecil
Krotoszyn
10.534 km
Pengisi vakum dengan pemuatan
HandtmannVF 628
HandtmannVF 628
Iklan kecil
Frankenberg/Sa.
10.848 km
Pompa ETANORM G 150-250
KSBETANORM G 150-250 G10
KSBETANORM G 150-250 G10
Iklan kecil
Tatabánya
10.498 km
Pompa sentrifugal, Etanorm mx 125-250 NA
KSBEtanorm mx 125-250 NA
KSBEtanorm mx 125-250 NA
Iklan kecil
Borken
11.250 km
Ruang uji iklim
VötschVCS 7033
VötschVCS 7033
Iklan Anda telah berhasil dihapus
Terjadi kesalahan