Ruang uji suhu, 680 literHeraeus Vötsch
VLM 3068/S -30 °C bis +125 °C
Ruang uji suhu, 680 liter
Heraeus Vötsch
VLM 3068/S -30 °C bis +125 °C
Tahun pembuatan
2010
Kondisi
Bekas
Lokasi
Borken 

Data mesin
- Nama mesin:
- Ruang uji suhu, 680 liter
- Pabrikan:
- Heraeus Vötsch
- Tahun pembuatan:
- 2010
- Kondisi:
- sangat baik (bekas)
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A22185287
- Nomor referensi:
- 23960
- Pembaruan:
- terakhir pada 23.06.2026
Deskripsi
Here we offer you a Heraeus Vötsch temperature test chest.
Vötsch Temperature Test Chest / Test Chamber VLM 3068/S, air-cooled
(top-loading material testing chambers)
Control Panel:
The control panel is mounted on a console on the temperature test chest. All control and operation commands can be triggered by simply touching the function symbols. The operating manual for the control panel is included.
Main Switch:
The main switch is located at the front of the temperature test chest.
Air Handling Compartment:
The air handling compartment is located inside the test chamber and contains the modules required for temperature regulation. In this compartment, the air is conditioned (cooled/heated) and circulated by the test chamber fan. Air is drawn in at the center of the side wall and, through the air baffles, re-enters the test chamber along the longitudinal sides.
Feedthroughs:
The temperature test chest can optionally be equipped with feedthroughs, allowing cables and testing devices to be routed into the test chamber. Feedthroughs: front 2 x 82 mm ∅, rear 1 x 85 mm ∅
Internal dimensions: Width 2,000 mm, Depth 570 mm, Height 600 mm
External dimensions: Width 3,000 mm, Depth 870 mm, Height 1,060 mm
Technical data:
Mechanical load capacity:
Max. load with test material (evenly distributed across chamber floor): 600 kg
Point load: 50 kg
Data for temperature tests:
Temperature range: -30 °C to +125 °C
Temperature deviation over time at chamber center: ±1 K
Rate of temperature change:
Heating approx. 1 K/min
Cooling approx. 2 K/min
Operating data:
Rated voltage: 3/N / PE AC 400 V ±10% 50 Hz
Rated power: 3 kW, Rated current: 9 A
Customer-side fuse: 16A slow-blow
Temperature test chest VLM 3068/S
Test chamber volume: approx. 680 l
Fjdpszgbmisfx Aa Hjpl
Weight: approx. 700 kg
Refrigerant: R-404A
Noise measurement: Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of delivery: (see picture)
(
Changes and errors in technical data 및 information reserved!)
If you have further questions, we will be happy to answer them for you by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Vötsch Temperature Test Chest / Test Chamber VLM 3068/S, air-cooled
(top-loading material testing chambers)
Control Panel:
The control panel is mounted on a console on the temperature test chest. All control and operation commands can be triggered by simply touching the function symbols. The operating manual for the control panel is included.
Main Switch:
The main switch is located at the front of the temperature test chest.
Air Handling Compartment:
The air handling compartment is located inside the test chamber and contains the modules required for temperature regulation. In this compartment, the air is conditioned (cooled/heated) and circulated by the test chamber fan. Air is drawn in at the center of the side wall and, through the air baffles, re-enters the test chamber along the longitudinal sides.
Feedthroughs:
The temperature test chest can optionally be equipped with feedthroughs, allowing cables and testing devices to be routed into the test chamber. Feedthroughs: front 2 x 82 mm ∅, rear 1 x 85 mm ∅
Internal dimensions: Width 2,000 mm, Depth 570 mm, Height 600 mm
External dimensions: Width 3,000 mm, Depth 870 mm, Height 1,060 mm
Technical data:
Mechanical load capacity:
Max. load with test material (evenly distributed across chamber floor): 600 kg
Point load: 50 kg
Data for temperature tests:
Temperature range: -30 °C to +125 °C
Temperature deviation over time at chamber center: ±1 K
Rate of temperature change:
Heating approx. 1 K/min
Cooling approx. 2 K/min
Operating data:
Rated voltage: 3/N / PE AC 400 V ±10% 50 Hz
Rated power: 3 kW, Rated current: 9 A
Customer-side fuse: 16A slow-blow
Temperature test chest VLM 3068/S
Test chamber volume: approx. 680 l
Fjdpszgbmisfx Aa Hjpl
Weight: approx. 700 kg
Refrigerant: R-404A
Noise measurement: Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of delivery: (see picture)
(
Changes and errors in technical data 및 information reserved!)
If you have further questions, we will be happy to answer them for you by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Sonsbeck
11.290 km
Mesin uji universal Mesin uji tarik
Hegewald & Peschke/HessH2,5TMNI
Hegewald & Peschke/HessH2,5TMNI
Iklan kecil
Sonsbeck
11.290 km
Mesin uji universal Mesin uji tarik
Hegewald & PeschkeH5TMCI
Hegewald & PeschkeH5TMCI
Iklan kecil
Wuppertal
11.240 km
Mesin uji universal / Mesin uji tarik
Darto GmbHPM50 Universalprüfmaschine
Darto GmbHPM50 Universalprüfmaschine
Iklan kecil
Kusel
11.270 km
Timbangan presisi
ShimadzuUX4200H
ShimadzuUX4200H
Iklan kecil
Duxford
11.686 km
Sartorius Practum 513 timbangan presisi
Sartorius513
Sartorius513
Iklan kecil
Sonsbeck
11.290 km
Mesin uji universal 10 kN
Hounsfield HessH10KM
Hounsfield HessH10KM
Iklan kecil
Bitburg
11.321 km
Kompresor piston
AirpressK 500 - 700 Super
AirpressK 500 - 700 Super
Iklan kecil
Duxford
11.686 km
Sartorius Tare CPA34001S neraca analitik
Sartorius Tare CPA34001S Analytical BalanceCPA34001S
Sartorius Tare CPA34001S Analytical BalanceCPA34001S
Iklan kecil
Duxford
11.686 km
Timbangan Sartorius Tare ENTRIS2202-1S
Sartorius Tare ENTRIS2202-1S BalanceSartorius Tare ENTRIS2202-1S Balance
Sartorius Tare ENTRIS2202-1S BalanceSartorius Tare ENTRIS2202-1S Balance
Iklan kecil
Wiefelstede
11.134 km
Temperaturfühler
W8Pt 100 Din
W8Pt 100 Din
Iklan Anda telah berhasil dihapus
Terjadi kesalahan


















































































