Deskripsi
2x Alpha-18-W-S with integrated redundant pump station
Standard Hyfra configuration:
* Frame construction made of stainless steel
* Economical, low-noise scroll compressors
* Pump integrated into the housing; Note: Required
inlet pressure: at least 0.05 bar!
* Unit equipped with control transformer, no neutral conductor required
* Flow monitor
* Frost protection monitoring
Isdpfx Aow I Eprsahjbf
* Fault indication with digital display
* Collective fault alarm, volt-free
* External activation
* Automatic fan speed switching
from low to high speed
* High-efficiency condenser with micro channel technology
* Non-cleanable plate evaporators for water
Special equipment:
Cooling capacity approx. 25 kW at +13°C tank temperature and ambient temperature of +32°C
Medium: water
All water-carrying pipes insulated
Chiller designed in accordance with current ECO Design Directive 2021
(adapted compressor, condenser, evaporator)
Housing LxWxH 1640 x 715 x 1560 mm
2 x CM3-4 pumps for tank circulation, each providing 3.5 m³/h at 1 bar
2 x CM5-5 process pumps (redundant design), each providing 4.5 m³/h at 3.5 bar
2 x EC fans with approx. 100 Pa external static pressure for short on-site air ducts
Flexible duct collar for easy connection to on-site ductwork system
Mounted control cabinet
2 x supply and return lines.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Standard Hyfra configuration:
* Frame construction made of stainless steel
* Economical, low-noise scroll compressors
* Pump integrated into the housing; Note: Required
inlet pressure: at least 0.05 bar!
* Unit equipped with control transformer, no neutral conductor required
* Flow monitor
* Frost protection monitoring
Isdpfx Aow I Eprsahjbf
* Fault indication with digital display
* Collective fault alarm, volt-free
* External activation
* Automatic fan speed switching
from low to high speed
* High-efficiency condenser with micro channel technology
* Non-cleanable plate evaporators for water
Special equipment:
Cooling capacity approx. 25 kW at +13°C tank temperature and ambient temperature of +32°C
Medium: water
All water-carrying pipes insulated
Chiller designed in accordance with current ECO Design Directive 2021
(adapted compressor, condenser, evaporator)
Housing LxWxH 1640 x 715 x 1560 mm
2 x CM3-4 pumps for tank circulation, each providing 3.5 m³/h at 1 bar
2 x CM5-5 process pumps (redundant design), each providing 4.5 m³/h at 3.5 bar
2 x EC fans with approx. 100 Pa external static pressure for short on-site air ducts
Flexible duct collar for easy connection to on-site ductwork system
Mounted control cabinet
2 x supply and return lines.