Kalorimeter pemindaian diferensialPerkin Elmer
DSC 8000, N5340524
Kalorimeter pemindaian diferensial
Perkin Elmer
DSC 8000, N5340524
EXW harga tetap ditambah PPN
€29.750
Kondisi
Bekas
Lokasi
Dresden 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Kalorimeter pemindaian diferensial
- Pabrikan:
- Perkin Elmer
- Model:
- DSC 8000, N5340524
- Kondisi:
- bekas
Harga & Lokasi
EXW harga tetap ditambah PPN
€29.750
- Lokasi:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A21283042
- Nomor referensi:
- LW43630
- Pembaruan:
- terakhir pada 20.02.2026
Deskripsi
PerkinElmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General Information:
Dual-furnace differential scanning calorimeter with power compensation. PerkinElmer DSC 8000 featuring Intracooler 2 for precise heat flow measurements from approx. –70 °C to 750 °C, offering high sensitivity and rapid thermal response.
General Device Specifications:
DSC Type: Dual-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance:
Standard Temperature Range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance:
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response time due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control:
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections:
USB
Ethernet (LAN)
Gas inlet fittings
Cooler unit connection
Power supply connection
Accessory connections (e.g., autosampler, high-pressure cell, UV/photo calorimeter module)
Temperature calibration interface
Technical Data:
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum Power: 400 VA
Accessories:
Kedpfxoyluice Ac Hodh
Cooling system Polyscience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler, 96 positions
High-pressure DSC cells, UV/photo calorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz / A / Ph: 50 / 7.5 / 1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Model: DSC8000
Type: N5340524
Condition: Used
General Information:
Dual-furnace differential scanning calorimeter with power compensation. PerkinElmer DSC 8000 featuring Intracooler 2 for precise heat flow measurements from approx. –70 °C to 750 °C, offering high sensitivity and rapid thermal response.
General Device Specifications:
DSC Type: Dual-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance:
Standard Temperature Range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance:
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response time due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control:
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections:
USB
Ethernet (LAN)
Gas inlet fittings
Cooler unit connection
Power supply connection
Accessory connections (e.g., autosampler, high-pressure cell, UV/photo calorimeter module)
Temperature calibration interface
Technical Data:
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum Power: 400 VA
Accessories:
Kedpfxoyluice Ac Hodh
Cooling system Polyscience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler, 96 positions
High-pressure DSC cells, UV/photo calorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz / A / Ph: 50 / 7.5 / 1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 351 8... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan




























