Ruang uji iklim XXL 3300 literVötsch
VC 7330/S -70°C bis +180°C
Ruang uji iklim XXL 3300 liter
Vötsch
VC 7330/S -70°C bis +180°C
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, DE
Hubungi
Rincian penawaran
- ID iklan:
- A17515278
- Nomor referensi:
- 24401
- pembaruan:
- terakhir pada 24.03.2025
Deskripsi
Vötsch
Model: VC 7330/S
Climate Chamber, Water-Cooled
Internal Volume: 3300 liters
Specifications for Temperature Testing:
Temperature Range: -70°C to +180°C
Spatial Temperature Deviation: ±1 to ±2 K (corresponds to temperature gradient) (2 to 4)
Temporal Temperature Fluctuation at Chamber Center: ±0.5 - 1 K
Rate of Temperature Change (according to IEC 60068-3-5):
Heating: 1.5 K/min
Cooling: 1.5 K/min
Specifications for Climatic Testing:
Temperature Range: +10°C to +90°C
Humidity Range: 10% r.h. to 98% r.h.
Temporal Temperature Fluctuation: ±0.2 to -0.5 K
Temporal Humidity Fluctuation: ±1% r.h. to ±3% r.h.
Dew Point Range: +5°C to +89°C
Mechanical Load Data:
Test Chamber Floor Load Capacity: 150 kg
Max. Chamber Floor Load: 250 kg
Test Chamber Dimensions: Width 2000 mm x Depth 1150 mm x Height 1510 mm
External Dimensions: Width 4000 mm x Depth 1450 mm x Height 2100 mm
Operating Data:
Hjdpfxeu Au Ers Adqsfn
Test Chamber Illumination: Halogen bulb 12 V, 20 W
Rated Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 15 kW
Rated Current: 34 A
External control via RS 232 interface possible.
Refrigerants: R404A / R23
Weight: 1550 kg
For your security as a buyer, please note the following information!
The following procedures are always performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
If you have further questions, we are happy to answer them by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Model: VC 7330/S
Climate Chamber, Water-Cooled
Internal Volume: 3300 liters
Specifications for Temperature Testing:
Temperature Range: -70°C to +180°C
Spatial Temperature Deviation: ±1 to ±2 K (corresponds to temperature gradient) (2 to 4)
Temporal Temperature Fluctuation at Chamber Center: ±0.5 - 1 K
Rate of Temperature Change (according to IEC 60068-3-5):
Heating: 1.5 K/min
Cooling: 1.5 K/min
Specifications for Climatic Testing:
Temperature Range: +10°C to +90°C
Humidity Range: 10% r.h. to 98% r.h.
Temporal Temperature Fluctuation: ±0.2 to -0.5 K
Temporal Humidity Fluctuation: ±1% r.h. to ±3% r.h.
Dew Point Range: +5°C to +89°C
Mechanical Load Data:
Test Chamber Floor Load Capacity: 150 kg
Max. Chamber Floor Load: 250 kg
Test Chamber Dimensions: Width 2000 mm x Depth 1150 mm x Height 1510 mm
External Dimensions: Width 4000 mm x Depth 1450 mm x Height 2100 mm
Operating Data:
Hjdpfxeu Au Ers Adqsfn
Test Chamber Illumination: Halogen bulb 12 V, 20 W
Rated Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 15 kW
Rated Current: 34 A
External control via RS 232 interface possible.
Refrigerants: R404A / R23
Weight: 1550 kg
For your security as a buyer, please note the following information!
The following procedures are always performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
If you have further questions, we are happy to answer them by phone.