Climatic test chamber 1300 liter dengan kontrol kelembapanVötsch
VCS 7130-15 -70°C bis +180°C
Climatic test chamber 1300 liter dengan kontrol kelembapan
Vötsch
VCS 7130-15 -70°C bis +180°C
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- pabrikan:
- Vötsch
- Kondisi:
- baik (bekas)
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, DE
Hubungi
Rincian penawaran
- ID iklan:
- A19437121
- Nomor referensi:
- 24666
- pembaruan:
- terakhir pada 20.08.2025
Deskripsi
Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation at the center of the test space: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature gradient: 1 to 4 K
Rate of temperature change:
Heating: 16 K/min
Cooling: 14.5 K/min
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at the center of the test space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at the center of the test space: ± 1 to ± 3% RH
Heat compensation: max. 8000W
Housing Dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test Chamber Illumination:
Halogen bulb 24 V, 50 W
3/N/PE AC 400V ±10% 50Hz
Nominal power: 44.0 kW
Nominal current: 63.0 A
Customer-side fuse: 100 A (slow-blow)
Max. heat output to the environment: 2.2 kW
Permissible test specimen weight:
Total load on grid shelves: 100 kg
Test chamber floor: 150 kg, insert shelf: 50 kg
Refrigerant: R 404A/R 23
Weight: 1900 kg
Your safety as a buyer – please note the following:
The following procedures are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant (if required)
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Dcjdowvgwbspfx Ag Usn
Condition: used
Scope of delivery: (See picture)
(Subject to technical changes and errors in the specifications!)
For further questions, please contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation at the center of the test space: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature gradient: 1 to 4 K
Rate of temperature change:
Heating: 16 K/min
Cooling: 14.5 K/min
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at the center of the test space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at the center of the test space: ± 1 to ± 3% RH
Heat compensation: max. 8000W
Housing Dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test Chamber Illumination:
Halogen bulb 24 V, 50 W
3/N/PE AC 400V ±10% 50Hz
Nominal power: 44.0 kW
Nominal current: 63.0 A
Customer-side fuse: 100 A (slow-blow)
Max. heat output to the environment: 2.2 kW
Permissible test specimen weight:
Total load on grid shelves: 100 kg
Test chamber floor: 150 kg, insert shelf: 50 kg
Refrigerant: R 404A/R 23
Weight: 1900 kg
Your safety as a buyer – please note the following:
The following procedures are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant (if required)
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Dcjdowvgwbspfx Ag Usn
Condition: used
Scope of delivery: (See picture)
(Subject to technical changes and errors in the specifications!)
For further questions, please contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan