1Vötsch
VT 7012 S2
1
Vötsch
VT 7012 S2
VB ditambah PPN
€11.025
Tahun pembuatan
2000
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- 1
- Pabrikan:
- Vötsch
- Model:
- VT 7012 S2
- Tahun pembuatan:
- 2000
- Kondisi:
- sangat baik (bekas)
- Jam operasional:
- 104.382 h
Harga & Lokasi
VB ditambah PPN
€11.025
- Lokasi:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A20729167
- Nomor referensi:
- 31747
- Pembaruan:
- terakhir pada 13.02.2026
Deskripsi
Vötsch Shock Test Chamber VT 7012 S2
System for Extreme Temperature Changes
The temperature shock test determines the resilience of components, devices, and other products against rapid fluctuations in ambient temperature. Test specimens are subjected to rapid temperature changes in air, with alternating upper and lower thermal loads. These cyclic stress conditions and accelerated aging caused by temperature shifts can reveal weaknesses in the specimens.
Vertical Arrangement of Test Chambers
• Ball screw drive for stable guidance of the specimen basket
• Basket load capacity: 50 kg (VT3 7012 S2)
• Specimens secured by all-round mesh in the basket
• High air recirculation rate ensures short temperature changeover times and uniform temperature distribution within the test chamber
• Warm chamber can be used as a temperature storage unit; cold chamber serves as a temperature cycling unit
• Minimal energy consumption
• No compressed air required
Manufacturer: Vötsch
Model: VT 7012 S2
Type: Temperature Shock Test Chamber
Test Chamber Volume: 120 l
Rated Voltage: 400 V
Rated Power: 10 kW
Rated Current: 25 A
Refrigerant: R452A
Cooling System: Water-cooled
Shock Cooling (Nitrogen cooling) via customer-supplied nitrogen feed
External Dimensions
Width: 930 mm
Depth: 2,115 mm
Height: 1,970 mm
Test Chamber Dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Degree of Protection
Unit: IP 42
Control Panel: IP 20
Switch Cabinet: IP 54
Performance Data for Temperature Testing in Single-Chamber Operation |
Temperature Range
Warm Chamber: +50°C to +220°C
Cold Chamber: -70°C to +70°C
Gtedpfx Agsx Exmts Rjw
Temporal Temperature Deviation: ±2 K (at steady state)
Spatial Temperature Deviation: ±2 K (at steady state in basket)
Warm Chamber Heating Rate: 11 K/min
Cold Chamber Cooling Rate: K/min
Cold Chamber Heating Rate: 2 K/min
Warm Chamber Cooling Rate: K/min
Observation Window: 355 x 355 mm
Tube Feedthrough: 67 mm
Year of Manufacture: 2000
Operating Hours: 104,382
Weight: 1,000 kg
Financing through our bank is available.
komplett-konzept.leasingo.de
More items—new and used—can be found in our shop! International shipping costs available on request!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
System for Extreme Temperature Changes
The temperature shock test determines the resilience of components, devices, and other products against rapid fluctuations in ambient temperature. Test specimens are subjected to rapid temperature changes in air, with alternating upper and lower thermal loads. These cyclic stress conditions and accelerated aging caused by temperature shifts can reveal weaknesses in the specimens.
Vertical Arrangement of Test Chambers
• Ball screw drive for stable guidance of the specimen basket
• Basket load capacity: 50 kg (VT3 7012 S2)
• Specimens secured by all-round mesh in the basket
• High air recirculation rate ensures short temperature changeover times and uniform temperature distribution within the test chamber
• Warm chamber can be used as a temperature storage unit; cold chamber serves as a temperature cycling unit
• Minimal energy consumption
• No compressed air required
Manufacturer: Vötsch
Model: VT 7012 S2
Type: Temperature Shock Test Chamber
Test Chamber Volume: 120 l
Rated Voltage: 400 V
Rated Power: 10 kW
Rated Current: 25 A
Refrigerant: R452A
Cooling System: Water-cooled
Shock Cooling (Nitrogen cooling) via customer-supplied nitrogen feed
External Dimensions
Width: 930 mm
Depth: 2,115 mm
Height: 1,970 mm
Test Chamber Dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Degree of Protection
Unit: IP 42
Control Panel: IP 20
Switch Cabinet: IP 54
Performance Data for Temperature Testing in Single-Chamber Operation |
Temperature Range
Warm Chamber: +50°C to +220°C
Cold Chamber: -70°C to +70°C
Gtedpfx Agsx Exmts Rjw
Temporal Temperature Deviation: ±2 K (at steady state)
Spatial Temperature Deviation: ±2 K (at steady state in basket)
Warm Chamber Heating Rate: 11 K/min
Cold Chamber Cooling Rate: K/min
Cold Chamber Heating Rate: 2 K/min
Warm Chamber Cooling Rate: K/min
Observation Window: 355 x 355 mm
Tube Feedthrough: 67 mm
Year of Manufacture: 2000
Operating Hours: 104,382
Weight: 1,000 kg
Financing through our bank is available.
komplett-konzept.leasingo.de
More items—new and used—can be found in our shop! International shipping costs available on request!
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2008
590 Iklan online
Kirim permintaan
Telepon & Faks
+49 2862 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Borken
11.250 km
Kamar uji kejut –80 °C hingga +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
Iklan kecil
Belanda
11.248 km
Universal Robots UR10e cell
Universal RobotsUR10e cell
Universal RobotsUR10e cell
Iklan kecil
Borken
11.250 km
Ruang uji kejut -80 ° C hingga + 220 ° C
VötschVT 7012 S2
VötschVT 7012 S2
Iklan kecil
Borken
11.250 km
Kamar uji kejut –75°C hingga +220°C
VötschVT 7012 S2
VötschVT 7012 S2
Iklan kecil
Borken
11.250 km
Pengocok
LDSV721 / TK 8000/-50/120
LDSV721 / TK 8000/-50/120
Iklan kecil
Borken
11.250 km
Ruang uji kejut
VötschVT 7012 S3
VötschVT 7012 S3
Iklan kecil
Bodzanów
10.355 km
Pompa vakum
BuschRA 0160 D
BuschRA 0160 D
Iklan Anda telah berhasil dihapus
Terjadi kesalahan