Ruang uji suhu 600 literVötsch
VTV 7060-5 -70°C bis +180°C
Ruang uji suhu 600 liter
Vötsch
VTV 7060-5 -70°C bis +180°C
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, DE
Hubungi
Rincian penawaran
- ID iklan:
- A19960910
- Nomor referensi:
- 24797
- pembaruan:
- terakhir pada 09.09.2025
Deskripsi
Heraeus Vötsch
Type: VTV 7060-5
Vibration and More ...
... Dynamic and Climatic Safety Testing
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
(with chamber opening for shaker, enabling vibration testing)
Effortless Elevation
With the electrically adjustable test chamber height, you can easily test even extra-tall specimens.
On-site adjustment to the final shaker height is possible.
Standard Features – Perfectly Detailed:
- Operating terminal: color touchscreen
- Microprocessor monitoring and control: S!MCON/32*-NET
- Digital I/O, potential-free
- Independent, adjustable temperature limiter tmin/tmax
- Adjustable software temperature limiter min./max.
- Serial RS 232 interface
- Potential-free contact for specimen shutdown
- Water-cooled refrigeration unit
- Calibration at 2 temperature setpoints
- Removable floor with cable duct
- Two cable ports: Ø 50 mm and Ø 125 mm
Vötsch Temperature Chamber VTV 7060-5
Dodpfx Aoxbgcrsg Uocn
Test chamber volume: 600 liters
Specifications for Temperature Testing:
- Temperature range: -70/+180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Temperature gradient: 1 to 4 K
- Heating rate: 6.0 K/min
- Cooling rate: 6.0 K/min
- Heat compensation at +20 °C: 5000 W
- Heat compensation at -20 °C: 5000 W
Chamber internal dimensions: W 800 mm x D 800 mm x H 950 mm
External dimensions: W 1225 mm x D 2890 mm x H 2150 mm
Height to bottom edge of test chamber min./max.: 660/1380 mm
Shaker opening: 710 mm Ø
Shaker opening: 700/700 mm
Electrical connection: 3/N/PE AC, 400 V±10 %, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Sound pressure level – 1 m in front: 75 dB(A)
Refrigerant: R-404A / R-23
Weight: approx. 650 kg
For Your Peace of Mind as a Buyer:
The following checks are performed on all chambers we offer before delivery:
1. Function test and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to technical changes and errors!)
Feel free to contact us by phone for further questions.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Type: VTV 7060-5
Vibration and More ...
... Dynamic and Climatic Safety Testing
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
(with chamber opening for shaker, enabling vibration testing)
Effortless Elevation
With the electrically adjustable test chamber height, you can easily test even extra-tall specimens.
On-site adjustment to the final shaker height is possible.
Standard Features – Perfectly Detailed:
- Operating terminal: color touchscreen
- Microprocessor monitoring and control: S!MCON/32*-NET
- Digital I/O, potential-free
- Independent, adjustable temperature limiter tmin/tmax
- Adjustable software temperature limiter min./max.
- Serial RS 232 interface
- Potential-free contact for specimen shutdown
- Water-cooled refrigeration unit
- Calibration at 2 temperature setpoints
- Removable floor with cable duct
- Two cable ports: Ø 50 mm and Ø 125 mm
Vötsch Temperature Chamber VTV 7060-5
Dodpfx Aoxbgcrsg Uocn
Test chamber volume: 600 liters
Specifications for Temperature Testing:
- Temperature range: -70/+180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Temperature gradient: 1 to 4 K
- Heating rate: 6.0 K/min
- Cooling rate: 6.0 K/min
- Heat compensation at +20 °C: 5000 W
- Heat compensation at -20 °C: 5000 W
Chamber internal dimensions: W 800 mm x D 800 mm x H 950 mm
External dimensions: W 1225 mm x D 2890 mm x H 2150 mm
Height to bottom edge of test chamber min./max.: 660/1380 mm
Shaker opening: 710 mm Ø
Shaker opening: 700/700 mm
Electrical connection: 3/N/PE AC, 400 V±10 %, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Sound pressure level – 1 m in front: 75 dB(A)
Refrigerant: R-404A / R-23
Weight: approx. 650 kg
For Your Peace of Mind as a Buyer:
The following checks are performed on all chambers we offer before delivery:
1. Function test and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to technical changes and errors!)
Feel free to contact us by phone for further questions.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan