Ruang uji iklim dengan kelembabanWeiss -72°C bis +180°C
WK3-340/70
Ruang uji iklim dengan kelembaban
Weiss -72°C bis +180°C
WK3-340/70
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Ruang uji iklim dengan kelembaban
- Pabrikan:
- Weiss -72°C bis +180°C
- Model:
- WK3-340/70
- Kondisi:
- sangat baik (bekas)
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A18791221
- Nomor referensi:
- 24566
- Pembaruan:
- terakhir pada 02.07.2025
Deskripsi
Weiss
Type: WK3-340/70
Weiss Climate Test Chamber, Air-cooled
Control unit: "Touchpanel"
All control and operating commands can be triggered by simply touching the function symbols on the "Touchpanel" control unit.
Leveling Feet
To compensate for floor unevenness and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Cable Ports
The test chamber is equipped with cable ports on both the right and left sides. These ports allow measurement cables and test equipment to be routed into the test space.
Standard cable ports installed:
R1: NW 125 mm
L1: NW 85 mm
Volume: 335 liters
Test chamber internal dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for temperature testing:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Gbsdpfx Ahsv Sr Hzeuok
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% r.h.
Operating data:
Test chamber lighting: Halogen lamp 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
On-site fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Safety information for buyers:
The following steps are carried out on our offered chambers in advance for your safety:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant as required
3. Leak test with certificate
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Subject to technical modifications and errors in specifications!)
If you have further questions, we will be happy to answer them by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Type: WK3-340/70
Weiss Climate Test Chamber, Air-cooled
Control unit: "Touchpanel"
All control and operating commands can be triggered by simply touching the function symbols on the "Touchpanel" control unit.
Leveling Feet
To compensate for floor unevenness and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Cable Ports
The test chamber is equipped with cable ports on both the right and left sides. These ports allow measurement cables and test equipment to be routed into the test space.
Standard cable ports installed:
R1: NW 125 mm
L1: NW 85 mm
Volume: 335 liters
Test chamber internal dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for temperature testing:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Gbsdpfx Ahsv Sr Hzeuok
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% r.h.
Operating data:
Test chamber lighting: Halogen lamp 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
On-site fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Safety information for buyers:
The following steps are carried out on our offered chambers in advance for your safety:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant as required
3. Leak test with certificate
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Subject to technical modifications and errors in specifications!)
If you have further questions, we will be happy to answer them by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Saarbrücken
11.313 km
Mesin pengukur optik Multisensor
MahrMS2VT Refurbished mit Garantie
MahrMS2VT Refurbished mit Garantie
Iklan kecil
Villingen-Schwenningen
11.219 km
Mesin pelubang berperforma tinggi
BRUDERERBSTA 50 USL
BRUDERERBSTA 50 USL
Iklan kecil
Grafenau
10.854 km
Mesin meninju otomatis
BRUDERERBSTA 300
BRUDERERBSTA 300
Iklan kecil
Contamine-sur-Arve
11.428 km
Pusat pemesinan horizontal
QUASERHX404BP/15C
QUASERHX404BP/15C
Iklan kecil
Bad Salzungen
11.049 km
Saringan bintang
Butzer - EVRESS / B2
Butzer - EVRESS / B2
Iklan kecil
Borken
11.250 km
Ruang iklim dengan kelembaban 34 liter
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
Iklan kecil
Graz
10.725 km
Mesin bubut CNC
WEILERE30X750 CNC-Drehmaschine-BJ 2007 - 8000h
WEILERE30X750 CNC-Drehmaschine-BJ 2007 - 8000h
Iklan kecil
Sremska Mitrovica
10.420 km
Hanya kabin kedap suara
for BRUDERER pressesSound insulating cabin
for BRUDERER pressesSound insulating cabin
Iklan kecil
Hilzingen
11.210 km
Bruderer BSTA 110
BRUDERERBSTA 110
BRUDERERBSTA 110
Iklan kecil
Wallerstein
11.064 km
Mesin bubut CNC
SpinnerTC400
SpinnerTC400
Iklan Anda telah berhasil dihapus
Terjadi kesalahan