Deskripsi
Weiss
Model: WKL 34/40
Weiss Climate Chamber Air-cooled
-40°C to +150°C
Internal volume: 34 liters
Standard built-in cable ports:
R1 NW 50 mm
Dwedpfsxvpp Rjx Afnjd
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature tests:
Temperature range: -40 to +150 °C
Temperature deviation in steady state (according to IEC 60068-3-5):
Temporal fluctuation in the center of the workspace: ±0.3 to ±1 K ±1 to ±2 K
Spatial deviation (temperature gradient): 2 to 4
Rate of temperature change (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specifications for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% RH
Temperature and humidity deviations (steady state, according to IEC 60068-3-5):
Temporal temperature fluctuation in the center of the workspace: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation in the center of the workspace: ±3 to ±5 % RH
Operating data:
Test space illumination: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ±10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-side fuse: 16A slow-blow
Heat emission, air-cooled test cabinets
Maximum heat dissipation to the environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important note:
“The table shown in the photos is not included in the sale.”
Important information for your security as a buyer!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors!)
If you have any further questions, please feel free to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Model: WKL 34/40
Weiss Climate Chamber Air-cooled
-40°C to +150°C
Internal volume: 34 liters
Standard built-in cable ports:
R1 NW 50 mm
Dwedpfsxvpp Rjx Afnjd
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature tests:
Temperature range: -40 to +150 °C
Temperature deviation in steady state (according to IEC 60068-3-5):
Temporal fluctuation in the center of the workspace: ±0.3 to ±1 K ±1 to ±2 K
Spatial deviation (temperature gradient): 2 to 4
Rate of temperature change (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specifications for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% RH
Temperature and humidity deviations (steady state, according to IEC 60068-3-5):
Temporal temperature fluctuation in the center of the workspace: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation in the center of the workspace: ±3 to ±5 % RH
Operating data:
Test space illumination: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ±10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-side fuse: 16A slow-blow
Heat emission, air-cooled test cabinets
Maximum heat dissipation to the environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important note:
“The table shown in the photos is not included in the sale.”
Important information for your security as a buyer!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors!)
If you have any further questions, please feel free to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan