Weiss temperature chamber
We are offering a Weiss temperature chamber.
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Specifications for temperature tests:
Temperature range: -70°C to +180°C
Temporal temperature deviation at center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient (according to IEC 60068-3-5): 1 to 4 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 5 K/min
Cooling: 5 K/min
Thermal compensation: max. 2750 W
Standard feedthroughs installed:
Nodpfx Anezfy Rwo Uecu
R1: NW 125 mm
L1: NW 50 mm
Dimensions:
Internal chamber dimensions: width 1100 mm x depth 950 mm x height 950 mm
External dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
Maximum load (evenly distributed) on chamber floor: 150 kg
Per grid shelf: 50 kg
Total shelf load: 100 kg
Operating data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated power: 27.0 kW
Rated current: 42.02 A
Heat dissipation (water-cooled test chambers): max. heat to ambient 1.3 kW
Noise measurement:
Sound pressure level: approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 960 kg
Type: WT11-1000/70/5
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors!)
For further questions, we are happy to assist you by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
We are offering a Weiss temperature chamber.
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Specifications for temperature tests:
Temperature range: -70°C to +180°C
Temporal temperature deviation at center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient (according to IEC 60068-3-5): 1 to 4 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 5 K/min
Cooling: 5 K/min
Thermal compensation: max. 2750 W
Standard feedthroughs installed:
Nodpfx Anezfy Rwo Uecu
R1: NW 125 mm
L1: NW 50 mm
Dimensions:
Internal chamber dimensions: width 1100 mm x depth 950 mm x height 950 mm
External dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
Maximum load (evenly distributed) on chamber floor: 150 kg
Per grid shelf: 50 kg
Total shelf load: 100 kg
Operating data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated power: 27.0 kW
Rated current: 42.02 A
Heat dissipation (water-cooled test chambers): max. heat to ambient 1.3 kW
Noise measurement:
Sound pressure level: approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 960 kg
Type: WT11-1000/70/5
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors!)
For further questions, we are happy to assist you by phone.