Deskripsi
CLEANROOM - ISO 8
| Requirements for Cleanroom ISO Class 8 | ISO 8 Cleanroom Classification |
To achieve ISO 8 air cleanliness in Cleanroom environments, a multi-stage air filtration system is typically implemented (e.g. pre-filter G4, filter F9, final filter H13). Airflow within the room is non-unidirectional (there is mixing of "clean" supply air with "dirty" air already present in the room). Air exhausts in ISO 8 rooms are located on the walls. The required number of air changes per hour depends on the operations performed in the room and the number of personnel present, but a target range is 10–40 air changes per hour. In ISO 8 class, personnel may remain in the room continuously. Workers may wear standard workwear, and guests should wear disposable gowns. It is recommended to maintain a minimum positive room pressure relative to adjacent areas at 5–10 Pa.
Requirements for equipment and materials intended for ISO 8 air cleanliness class Cleanrooms (maximum average number of particles released, when: number of samples taken = 100; measurement performed according to ISO 14644-14 in a cleanliness class at least one better than device usage class; particles/m³). Detailed description in photos.
Technical drawings attached in photos.
Ventilation Description
Iedpfx Aaeq H H Rujhotr
The goal of the installed ventilation system was to achieve the following air parameters in the Cleanroom. Construction was carried out using the GBD PHARMA 2000 system, compliant with all requirements for ‘cleanrooms’ in the highest air cleanliness classes.
Parameters for the installation: a. Air cleanliness - ISO 8. b. Temperature 19–23°C c. humidity max 38%.
a. To ensure the required supply air cleanliness, a DOSPEL air handling unit with a maximum capacity of V = 3500 m³/h [up to 15 air changes per hour] was used. The unit is equipped with bag filters: pre-filter FK EU5/EC2 and fine filter FK-EU9/EC2. Additionally, HEPA 11 filters by EUFILTER were fitted in ceiling diffusers. Catalog sheets in section H6. As a result, with a measured capacity of 3264 m³/h, ISO 7 cleanroom class [class “C”] was achieved at rest and ISO 8 class [class “D”] during operation.
b. The temperature range of 19–23°C is easily maintained by the oversized cooler and unit at 25% fresh air share.
c. To achieve the required conditions during summer with outside temperatures up to 30°C and humidity around 80%, a 31.4 kW freon cooler and a 33.5 kW refrigeration unit were used. The refrigeration unit is manufactured by FUJITSU and supplied by Klimatherm Gdańsk.
The room maintains automatically regulated overpressure relative to external pressure – pressure difference at doors: 15 Pa. The ventilation automation allows for an “economy” mode, in which the system works in a closed loop, maintaining 15 Pa overpressure.
Technical data attached in the photos.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
| Requirements for Cleanroom ISO Class 8 | ISO 8 Cleanroom Classification |
To achieve ISO 8 air cleanliness in Cleanroom environments, a multi-stage air filtration system is typically implemented (e.g. pre-filter G4, filter F9, final filter H13). Airflow within the room is non-unidirectional (there is mixing of "clean" supply air with "dirty" air already present in the room). Air exhausts in ISO 8 rooms are located on the walls. The required number of air changes per hour depends on the operations performed in the room and the number of personnel present, but a target range is 10–40 air changes per hour. In ISO 8 class, personnel may remain in the room continuously. Workers may wear standard workwear, and guests should wear disposable gowns. It is recommended to maintain a minimum positive room pressure relative to adjacent areas at 5–10 Pa.
Requirements for equipment and materials intended for ISO 8 air cleanliness class Cleanrooms (maximum average number of particles released, when: number of samples taken = 100; measurement performed according to ISO 14644-14 in a cleanliness class at least one better than device usage class; particles/m³). Detailed description in photos.
Technical drawings attached in photos.
Ventilation Description
Iedpfx Aaeq H H Rujhotr
The goal of the installed ventilation system was to achieve the following air parameters in the Cleanroom. Construction was carried out using the GBD PHARMA 2000 system, compliant with all requirements for ‘cleanrooms’ in the highest air cleanliness classes.
Parameters for the installation: a. Air cleanliness - ISO 8. b. Temperature 19–23°C c. humidity max 38%.
a. To ensure the required supply air cleanliness, a DOSPEL air handling unit with a maximum capacity of V = 3500 m³/h [up to 15 air changes per hour] was used. The unit is equipped with bag filters: pre-filter FK EU5/EC2 and fine filter FK-EU9/EC2. Additionally, HEPA 11 filters by EUFILTER were fitted in ceiling diffusers. Catalog sheets in section H6. As a result, with a measured capacity of 3264 m³/h, ISO 7 cleanroom class [class “C”] was achieved at rest and ISO 8 class [class “D”] during operation.
b. The temperature range of 19–23°C is easily maintained by the oversized cooler and unit at 25% fresh air share.
c. To achieve the required conditions during summer with outside temperatures up to 30°C and humidity around 80%, a 31.4 kW freon cooler and a 33.5 kW refrigeration unit were used. The refrigeration unit is manufactured by FUJITSU and supplied by Klimatherm Gdańsk.
The room maintains automatically regulated overpressure relative to external pressure – pressure difference at doors: 15 Pa. The ventilation automation allows for an “economy” mode, in which the system works in a closed loop, maintaining 15 Pa overpressure.
Technical data attached in the photos.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2023
Kirim permintaan
Telepon & Faks
+48 728 4... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Hochdorf
11.141 km
Unit Pendingin Suhu (TCU)
SingleOil Advanced D2
SingleOil Advanced D2
Iklan kecil
Burgdorf
11.028 km
Kamar bersih / Kamar bersih ISO 6
ABNStericube Matrix ISO 6
ABNStericube Matrix ISO 6
Iklan kecil
Niederlangen
11.202 km
Ekstraksi
NOVUSAirtower FT 20.000
NOVUSAirtower FT 20.000
Iklan kecil
Bad Hönningen
11.253 km
Wadah hidup
Bürocontainer / Wohncontainer/ Baucontainer Modell Grau
Bürocontainer / Wohncontainer/ Baucontainer Modell Grau
Iklan kecil
Krotoszyn
10.534 km
Mesin Pengemas/Pengemas
MultivacR230
MultivacR230
Iklan kecil
Graben-Neudorf
11.201 km
Mesin pengemas vakum
GEAPowerPak XT 420
GEAPowerPak XT 420
Iklan kecil
Braunschweig
10.991 km
Mesin pengemas thermoforming / blister
AUTOVAKM320
AUTOVAKM320
Iklan kecil
Ahaus
11.235 km
Tiang jib crane
ABUSLS / 4000 MM x 500 KG
ABUSLS / 4000 MM x 500 KG
Iklan kecil
Laupheim
11.121 km
Mesin pengemas blister
UhlmannBEC700
UhlmannBEC700
Iklan kecil
Zuchwil
11.313 km
Mesin pemukul
StähliFLM 750
StähliFLM 750
Iklan Anda telah berhasil dihapus
Terjadi kesalahan