HPLC (Kromatografi Cair Kinerja Tinggi)ThermoFisher / Dionex
UltiMate 3000
HPLC (Kromatografi Cair Kinerja Tinggi)
ThermoFisher / Dionex
UltiMate 3000
harga tetap ditambah PPN
€10.000
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- HPLC (Kromatografi Cair Kinerja Tinggi)
- Pabrikan:
- ThermoFisher / Dionex
- Model:
- UltiMate 3000
- Kondisi:
- bekas
Harga & Lokasi
harga tetap ditambah PPN
€10.000
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, DE

Hubungi
Rincian penawaran
- ID iklan:
- A20416260
- Nomor referensi:
- 24837
- Pembaruan:
- terakhir pada 30.10.2025
Deskripsi
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
Prjdpfxjxtb Efe Ab Hec
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column identification: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion
(10 ports or 6 ports)
Flow splitter: Nano-, capillary- or thermostated micro-flow splitter with
flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter,
independent of solvent composition and back pressure
Column flow rate range: 50 nL/min to 2.5 mL/min using a predefined splitter and
active flow control
Flow rate selection range: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro-LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter output
Max. column pressure: 35 MPa (4900 psi)
Wetted parts: Fused silica, stainless steel (1.4571, 316L), PEEK;
Waste line: PTFE, aluminium oxide (Al2O3)
Safety features: Moisture sensor, gas sensor, and leak detector for the flow control valve
VWD
Optical design: Dual-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength:
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
Prjdpfxjxtb Efe Ab Hec
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column identification: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion
(10 ports or 6 ports)
Flow splitter: Nano-, capillary- or thermostated micro-flow splitter with
flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter,
independent of solvent composition and back pressure
Column flow rate range: 50 nL/min to 2.5 mL/min using a predefined splitter and
active flow control
Flow rate selection range: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro-LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter output
Max. column pressure: 35 MPa (4900 psi)
Wetted parts: Fused silica, stainless steel (1.4571, 316L), PEEK;
Waste line: PTFE, aluminium oxide (Al2O3)
Safety features: Moisture sensor, gas sensor, and leak detector for the flow control valve
VWD
Optical design: Dual-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength: