Sel simulasi iklim walk-inTIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
Sel simulasi iklim walk-in
TIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A18478886
- Nomor referensi:
- 23515
- Pembaruan:
- terakhir pada 10.02.2025
Deskripsi
en_TIRA
Type: TCZ 4022 S -2K
Description: Climate Simulation Chamber, Air-Cooled
System Configuration:
The system consists of the following main components:
- Walk-in, insulated chamber
- Air handling room
- Humidification unit
- Machine room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
Lsdpfsvx S Hhex Adweai
- Temperature range: -40...+140°C
- Temperature consistency, supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature consistency, supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (to DIN 50011): approx. 2.0 K/min (without thermal test chamber load, to DIN 50011 / EN 60068, or test specimen in the range -30°C...+85°C)
- Cooling rate (to DIN 50011): approx. 2.0 K/min (without thermal test chamber load, to DIN 50011 / EN 60068, or test specimen in the range -30°C...+85°C)
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% r.h. (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity consistency (in supply air, temporal): ≤ ±2.5% r.h. (measured in supply air)
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% r.h. (without thermal test chamber load, with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (W x D x H): approx. 2260 x 4648 x 2260 mm
- External dimensions (W x D x H): approx. 2660 x 6460 x 2800 mm
- Clear door opening of test chamber door (W x H): 2260 x 2260 mm
- Climate module KB 127 (W x D x H): 1700 x 800 x 1400 mm
- Control cabinet (W x D x H): 800 x 500 x 2000 mm
Design:
Airflow:
- Supply air: perforated plate on rear wall, ceiling area
- Exhaust air: perforated plate on rear wall, floor area
Temperature Control:
- Direct cooling by evaporating refrigerant in a finned heat exchanger
- Heating with electric resistance heaters
Dehumidification:
- Direct dehumidification by evaporating refrigerant in a heat exchanger
Interior cladding: stainless steel
External cladding: galvanized, plastic-coated steel sheet
Floor design: stainless steel, floor load 15,000 N/m², wheel load (contact area ≥4 cm²) 1,500 N/wheel
Door: double-leaf door, stainless steel, painted exterior with observation window (W x H) 1000 x 1000 mm
Test chamber lighting: 4 spotlights at 500 W each
Insulation: double-layer, 80 mm PUR foam, 120 mm mineral wool
Refrigeration unit (1 piece): Bitzer 6G-30.2Y
Refrigerant: R449A
Refrigeration oil: SEZ 32
Steam humidifier (1 piece): EDB 40
Colors:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system approx. 4,900 kg
- Machine module KB 127 approx. 750 kg
- Control cabinet approx. 120 kg
- Humidification unit approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10% 3/PE N 50 Hz
- Rated power: 95 kW
- Rated current: 150 A
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Type: TCZ 4022 S -2K
Description: Climate Simulation Chamber, Air-Cooled
System Configuration:
The system consists of the following main components:
- Walk-in, insulated chamber
- Air handling room
- Humidification unit
- Machine room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
Lsdpfsvx S Hhex Adweai
- Temperature range: -40...+140°C
- Temperature consistency, supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature consistency, supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (to DIN 50011): approx. 2.0 K/min (without thermal test chamber load, to DIN 50011 / EN 60068, or test specimen in the range -30°C...+85°C)
- Cooling rate (to DIN 50011): approx. 2.0 K/min (without thermal test chamber load, to DIN 50011 / EN 60068, or test specimen in the range -30°C...+85°C)
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% r.h. (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity consistency (in supply air, temporal): ≤ ±2.5% r.h. (measured in supply air)
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% r.h. (without thermal test chamber load, with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (W x D x H): approx. 2260 x 4648 x 2260 mm
- External dimensions (W x D x H): approx. 2660 x 6460 x 2800 mm
- Clear door opening of test chamber door (W x H): 2260 x 2260 mm
- Climate module KB 127 (W x D x H): 1700 x 800 x 1400 mm
- Control cabinet (W x D x H): 800 x 500 x 2000 mm
Design:
Airflow:
- Supply air: perforated plate on rear wall, ceiling area
- Exhaust air: perforated plate on rear wall, floor area
Temperature Control:
- Direct cooling by evaporating refrigerant in a finned heat exchanger
- Heating with electric resistance heaters
Dehumidification:
- Direct dehumidification by evaporating refrigerant in a heat exchanger
Interior cladding: stainless steel
External cladding: galvanized, plastic-coated steel sheet
Floor design: stainless steel, floor load 15,000 N/m², wheel load (contact area ≥4 cm²) 1,500 N/wheel
Door: double-leaf door, stainless steel, painted exterior with observation window (W x H) 1000 x 1000 mm
Test chamber lighting: 4 spotlights at 500 W each
Insulation: double-layer, 80 mm PUR foam, 120 mm mineral wool
Refrigeration unit (1 piece): Bitzer 6G-30.2Y
Refrigerant: R449A
Refrigeration oil: SEZ 32
Steam humidifier (1 piece): EDB 40
Colors:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system approx. 4,900 kg
- Machine module KB 127 approx. 750 kg
- Control cabinet approx. 120 kg
- Humidification unit approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10% 3/PE N 50 Hz
- Rated power: 95 kW
- Rated current: 150 A
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2012
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan