Vötsch Climate Test Chamber
We offer here a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Dcodpfx Ajqnutmjg Ujn
Test chamber dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Volume: 990 liters
Cable port: Ø 125 mm / Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ± 0.1 to ± 0.5 K
- Spatial temperature uniformity: ± 0.5 to ± 1.5 K
- Temperature change rate: Heating 4.0 K/min, Cooling 3.0 K/min
- Max. heat compensation at +20°C: 4,500 W
Specifications for climatic tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ± 0.1 to ± 0.3 K
- Spatial temperature uniformity: ± 0.5 to ± 1.0 K
- Temporal humidity deviation: ± 1 to ± 3% r.H.
- Max. heat compensation: 500 W
Mains voltage: 3/N/PE AC 400V ±10% 50 Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important information for buyer safety!
The following procedures are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications are subject to change and error!)
For further questions, please do not hesitate to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
We offer here a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Dcodpfx Ajqnutmjg Ujn
Test chamber dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Volume: 990 liters
Cable port: Ø 125 mm / Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ± 0.1 to ± 0.5 K
- Spatial temperature uniformity: ± 0.5 to ± 1.5 K
- Temperature change rate: Heating 4.0 K/min, Cooling 3.0 K/min
- Max. heat compensation at +20°C: 4,500 W
Specifications for climatic tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ± 0.1 to ± 0.3 K
- Spatial temperature uniformity: ± 0.5 to ± 1.0 K
- Temporal humidity deviation: ± 1 to ± 3% r.H.
- Max. heat compensation: 500 W
Mains voltage: 3/N/PE AC 400V ±10% 50 Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important information for buyer safety!
The following procedures are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications are subject to change and error!)
For further questions, please do not hesitate to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
iklan kecil

11.250 km
Ruang uji iklim dengan kelembaban
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
iklan kecil

11.250 km
Ruang uji iklim
VötschVC³ 4100
VötschVC³ 4100
Iklan Anda telah berhasil dihapus
Terjadi kesalahan