Kabinet suhu 990 literWeiss
WT3-1000/40 -40°C bis +180°C
Kabinet suhu 990 liter
Weiss
WT3-1000/40 -40°C bis +180°C
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A15931990
- Nomor referensi:
- 24089
- Pembaruan:
- terakhir pada 15.11.2024
Deskripsi
Weiss
Type: WT3-1000/40
Nsdpfx Ajthhw Ajbgjdd
Weiss Temperature Test Chamber with S!MCON / 32 Controller, Water-Cooled
Operating Unit: "Touch Panel"
All control and operating commands can be triggered at the operating unit "Touch Panel" simply by touching the function icons.
Leveling Feet
To compensate for floor unevenness and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
Feedthroughs are installed on both the right and left sides of the test chamber. These allow measurement leads and test equipment to be routed into the test room.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Volume: approx. 990 liters
Test Chamber Internal Dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External Dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Data for Temperature Testing:
Temperature Range: -40 to +180 °C
Temporal temperature deviation at center of working space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 4500 W
Operating Data:
Test chamber lighting: Halogen bulbs 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ±10%, 50 Hz
Rated current: 22.0 A, Rated output: 11.5 kW
Required fuse by customer: 32 A slow-blow
Sound pressure level (approx.):
Measured at a distance of 1 m in front, at a height of 1 m: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional inspection and replacement of necessary components
2. New charging with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data. All specifications subject to confirmation!)
If you have further questions, we will be happy to answer them by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Type: WT3-1000/40
Nsdpfx Ajthhw Ajbgjdd
Weiss Temperature Test Chamber with S!MCON / 32 Controller, Water-Cooled
Operating Unit: "Touch Panel"
All control and operating commands can be triggered at the operating unit "Touch Panel" simply by touching the function icons.
Leveling Feet
To compensate for floor unevenness and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
Feedthroughs are installed on both the right and left sides of the test chamber. These allow measurement leads and test equipment to be routed into the test room.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Volume: approx. 990 liters
Test Chamber Internal Dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External Dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Data for Temperature Testing:
Temperature Range: -40 to +180 °C
Temporal temperature deviation at center of working space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 4500 W
Operating Data:
Test chamber lighting: Halogen bulbs 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ±10%, 50 Hz
Rated current: 22.0 A, Rated output: 11.5 kW
Required fuse by customer: 32 A slow-blow
Sound pressure level (approx.):
Measured at a distance of 1 m in front, at a height of 1 m: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional inspection and replacement of necessary components
2. New charging with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data. All specifications subject to confirmation!)
If you have further questions, we will be happy to answer them by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2012
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan

















