Kamar uji kejut –80 °C hingga +220 °CVötsch
VT 7012 S2
Kamar uji kejut –80 °C hingga +220 °C
Vötsch
VT 7012 S2
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
- Nama mesin:
- Kamar uji kejut –80 °C hingga +220 °C
- Pabrikan:
- Vötsch
- Model:
- VT 7012 S2
- Kondisi:
- sangat baik (bekas)
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Rincian penawaran
- ID iklan:
- A20740352
- Nomor referensi:
- 24920
- Pembaruan:
- terakhir pada 11.12.2025
Deskripsi
Vötsch
type: VT 7012 S2
water-cooled
Hot chamber:
The temperature control range of the hot chamber is from +50°C to +220°C
Temporal temperature deviation at centre of usable space: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change
Heating: 11 K/min
Cold chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at centre of usable space: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 litres
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Fjdpjx E Tkaofx Acuegk
Port: ∅ 67 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R404A / R23
Weight: 1000 kg
Important safety information for buyers:
The following checks and services are carried out on our offered chambers in advance:
1. Functional test and replacement of necessary components
2. New charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data and details subject to change and errors!)
If you have any further questions, feel free to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
type: VT 7012 S2
water-cooled
Hot chamber:
The temperature control range of the hot chamber is from +50°C to +220°C
Temporal temperature deviation at centre of usable space: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change
Heating: 11 K/min
Cold chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at centre of usable space: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 litres
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Fjdpjx E Tkaofx Acuegk
Port: ∅ 67 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R404A / R23
Weight: 1000 kg
Important safety information for buyers:
The following checks and services are carried out on our offered chambers in advance:
1. Functional test and replacement of necessary components
2. New charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data and details subject to change and errors!)
If you have any further questions, feel free to contact us by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Terdaftar sejak: 2012
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik bagi Anda.
Iklan kecil
Borken
11.254 km
1
VötschVT 7012 S2
VötschVT 7012 S2
Iklan kecil
Borken
11.250 km
Kamar uji kejut –80 °C hingga +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
Iklan kecil
Borken
11.250 km
Ruang uji kejut -80 ° C hingga + 220 ° C
VötschVT 7012 S2
VötschVT 7012 S2
Iklan kecil
Borken
11.250 km
Ruang uji kejut +50 - 220 ° C -80 - +70 ° C
VötschVT 7012 S2 (6603)
VötschVT 7012 S2 (6603)
Iklan Anda telah berhasil dihapus
Terjadi kesalahan