Ruang suhu 2000 literCTS
T-40/2000 -40°C bis +180°C
Ruang suhu 2000 liter
CTS
T-40/2000 -40°C bis +180°C
Kondisi
Bekas
Lokasi
Borken 

Gambar menunjukkan
Tampilkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, DE
Hubungi
Rincian penawaran
- ID iklan:
- A17202157
- Nomor referensi:
- 24329
- pembaruan:
- terakhir pada 15.11.2024
Deskripsi
CTS
Type: T-40/2000
Air-cooled Temperature Test Chamber
Technical Specifications:
Cooling Unit:
- Air-cooled, low-noise, fully hermetic, infinitely variable power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerant R404A
Door:
- Fully opening door, left-hand hinge
- One-hand operation, lockable
Shelving Grate:
- Stainless steel, support surface 970 x 980 + 500 mm
- Maximum load per shelf: 35 kg
- Total load with maximum shelf configuration: 100 kg
Test Chamber Lighting:
- 3x halogen lamps, 20 W, 12 V
Control System:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric input of setpoints
- Plain text fault messages
- RS 232 interface
- Free switching channels for customer-specific test item control
Temperature Range: -40°C to +180°C
Rated Voltage: 400V 3/N 50Hz
Rated Power: 10.4 kW
Rated Current: 17.2 A
Compressor: TFH2516Z
Piping Feedthrough: NW 50
Control Panel Window: 570 x 710 mm
Electrical connection cable length: 5 m
Technical Performance Data:
Temperature Tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
Fodpfoup T Uqsx Adqopn
- Heating: 2.5 K/min
- Cooling: 1.5 K/min
Heat Emission:
- Approx. 2500 W at +20°C
- Approx. 2100 W at 0°C
- Approx. 1500 W at -20°C
Technical data based on ambient temperature +25°C, rated voltage 400V, without test specimens, no irradiation, and no additional equipment.
Dimensions:
- Test volume: 2000 litres
- Test chamber internal dimensions: Height 900 mm, Width 975 mm, Depth 2200 mm
- External dimensions: Height 1950 mm, Width 1290 mm, Depth 3145 mm
Operating Data:
- Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
- Rated power: 17.2 kW
- Protection class: IP 22
- Condensate drain: gravity, R 1/2" internal thread
- Sound pressure level (measured at 1 m front distance, according to DIN EN ISO 3744): < 55 dB(A)
- Weight: approx. 1200 kg
Important Information for Your Safety as a Buyer!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful verification, the chambers undergo a documented test run
Condition: Used
Scope of delivery: (see image)
(Technical data, specifications, and information are subject to change and correction!)
We are happy to answer further questions for you by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Type: T-40/2000
Air-cooled Temperature Test Chamber
Technical Specifications:
Cooling Unit:
- Air-cooled, low-noise, fully hermetic, infinitely variable power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerant R404A
Door:
- Fully opening door, left-hand hinge
- One-hand operation, lockable
Shelving Grate:
- Stainless steel, support surface 970 x 980 + 500 mm
- Maximum load per shelf: 35 kg
- Total load with maximum shelf configuration: 100 kg
Test Chamber Lighting:
- 3x halogen lamps, 20 W, 12 V
Control System:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric input of setpoints
- Plain text fault messages
- RS 232 interface
- Free switching channels for customer-specific test item control
Temperature Range: -40°C to +180°C
Rated Voltage: 400V 3/N 50Hz
Rated Power: 10.4 kW
Rated Current: 17.2 A
Compressor: TFH2516Z
Piping Feedthrough: NW 50
Control Panel Window: 570 x 710 mm
Electrical connection cable length: 5 m
Technical Performance Data:
Temperature Tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
Fodpfoup T Uqsx Adqopn
- Heating: 2.5 K/min
- Cooling: 1.5 K/min
Heat Emission:
- Approx. 2500 W at +20°C
- Approx. 2100 W at 0°C
- Approx. 1500 W at -20°C
Technical data based on ambient temperature +25°C, rated voltage 400V, without test specimens, no irradiation, and no additional equipment.
Dimensions:
- Test volume: 2000 litres
- Test chamber internal dimensions: Height 900 mm, Width 975 mm, Depth 2200 mm
- External dimensions: Height 1950 mm, Width 1290 mm, Depth 3145 mm
Operating Data:
- Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
- Rated power: 17.2 kW
- Protection class: IP 22
- Condensate drain: gravity, R 1/2" internal thread
- Sound pressure level (measured at 1 m front distance, according to DIN EN ISO 3744): < 55 dB(A)
- Weight: approx. 1200 kg
Important Information for Your Safety as a Buyer!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful verification, the chambers undergo a documented test run
Condition: Used
Scope of delivery: (see image)
(Technical data, specifications, and information are subject to change and correction!)
We are happy to answer further questions for you by phone.
Iklan ini diterjemahkan secara otomatis. Kesalahan terjemahan mungkin terjadi.
Penyedia
Catatan: Daftar gratis atau masuk, untuk mengakses semua informasi.
Kirim permintaan
Telepon & Faks
+49 2861 ... iklan
Iklan Anda telah berhasil dihapus
Terjadi kesalahan